Correction of Non‐Uniform Rotational Distortion in the Proximally Controlled Endoscopic <scp>OCTA</scp>

Endoscopic Optical Coherence Tomography (OCT) can provide high-resolution cross-sectional images for internal organ tissues. Combining the endoscopic imaging with Optical Coherence Tomography Angiography (OCTA), information of blood vessels in superficial lumen tissues is expected to be acquired. However, in endoscopic OCT systems using proximal scanning probes, performance of OCTA encounters significant challenges due to non-uniform rotational distortion (NURD) caused by the non-constant rotation of the distal imaging unit. In this study, we proposed a registration method for endoscopic OCTA imaging in a proximally controlled OCT System. Global registration and A-line registration were employed to correct the distortion caused by mechanical friction between the catheter sheath and torque coil. Experimental performances in both microfluidic channel and rat rectum show significant correction of NURD. Our study achieved the first implementation of endoscopic OCTA under a spiral B-scan rotation scheme in a proximally controlled OCT system, facilitating clear visualization of blood flow.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2025-02-04
DOI
https://doi.org/10.1002/jbio.202400467
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of Non‐Uniform Rotational Distortion in the Proximally Controlled Endoscopic OCTA

Cuixia Dai, Xiang‐Fei Feng, Wenjuan Wu, Shuhao Fan et al.
Journal of Biophotonics
Optical Coherence Tomography Applications
article

Correction of Non‐Uniform Rotational Distortion in the Proximally Controlled Endoscopic OCTA

Cuixia Dai, Xiang‐Fei Feng, Wenjuan Wu, Shuhao Fan, Qiang Li, Huanhuan Yu, Chen Niu, Zehua Guan
article en

Abstract

Endoscopic Optical Coherence Tomography (OCT) can provide high-resolution cross-sectional images for internal organ tissues. Combining the endoscopic imaging with Optical Coherence Tomography Angiography (OCTA), information of blood vessels in superficial lumen tissues is expected to be acquired. However, in endoscopic OCT systems using proximal scanning probes, performance of OCTA encounters significant challenges due to non-uniform rotational distortion (NURD) caused by the non-constant rotation of the distal imaging unit. In this study, we proposed a registration method for endoscopic OCTA imaging in a proximally controlled OCT System. Global registration and A-line registration were employed to correct the distortion caused by mechanical friction between the catheter sheath and torque coil. Experimental performances in both microfluidic channel and rat rectum show significant correction of NURD. Our study achieved the first implementation of endoscopic OCTA under a spiral B-scan rotation scheme in a proximally controlled OCT system, facilitating clear visualization of blood flow.

Journal of BiophotonicsVol. 18(4)
Shanghai Jiao Tong University (CN), XinHua Hospital (CN), Shanghai Institute of Technology (CN)
National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Shanghai Institute of Technology, Science and Technology Innovation Plan Of Shanghai Science and Technology Commission
Openalex Percentile: Top 98%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.