Positive pressure ventilation improves oxygen saturation at altitude during recreational aviation: A pilot study

We investigated whether a commercial bi-level positive airway pressure (BPAP) device, would improve peripheral oxygen saturation (SpO<sub>2</sub>) during recreational aviation up to 12,500 feet without supplemental oxygen. Ten adults with recreational flight experience (age:47 ± 14; female = 5) completed a standardized flight profile in an unpressurised aircraft, involving randomized crossover design at 8,000 feet and 12,500 feet with BPAP or control. SpO<sub>2</sub>, middle cerebral artery velocity (MCAv), heart rate (HR), respiratory rate (RR), and relative tidal volume (TV) index were measured continuously. Psychomotor vigilance test (3-min) assessed reaction time halfway through taxi and altitude stages. Altitude significantly (p < 0.05) decreased mean SpO<sub>2</sub>, MCAv, and RR, and increased TV index and HR. There was no effect of altitude (p > 0.05) on reaction time. BPAP increased mean SpO<sub>2</sub> at 8,000 feet [Control: 92 ± 1%; BPAP: 94 ± 2%; mean difference (MD) = 2 ± 2%; p = 0.002] and 12,500 feet [Control: 86 ± 4%; BPAP: 89 ± 4%; MD = 2 ± 3%; p = 0.013]. BPAP lowered MCAv at 8,000 feet [Control: 53 ± 10 cm/s; BPAP: 50 ± 9 cm/s; MD = -3 ± 2 cm/s; p = 0.001] and 12,500 feet [Control: 52 ± 10 cm/s; BPAP: 50 ± 8 cm/s; MD = -2 ± 3 cm/s; p = 0.041]. BPAP increased TV index at 8,000 feet (Control: 6.6 ± 1.3; BPAP:8.1 ± 1.8; MD = 1.9 ± 0.8; p < 0.001) but not 12,500 feet, without effect on RR or reaction time. This study provides preliminary results that BPAP may improve mean SpO<sub>2</sub> for recreational aviators up to 12,500 feet without supplemental oxygen.

Authors

Institutions

Publication Details

Journal
Physiological Reports
Published
2025-02-01
DOI
https://doi.org/10.14814/phy2.70210
Citations
3
Primary Topic
High Altitude and Hypoxia
Type
article
Field-Weighted Citation Impact
5.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Positive pressure ventilation improves oxygen saturation at altitude during recreational aviation: A pilot study

Jenna L. Taylor, Bruce D. Johnson, Douglas T. Summerfield, John B. Downs et al.
3 citations
Physiological Reports
High Altitude and Hypoxia
5.45
article

Positive pressure ventilation improves oxygen saturation at altitude during recreational aviation: A pilot study

Jenna L. Taylor, Bruce D. Johnson, Douglas T. Summerfield, John B. Downs, Aidan K. Downs, Crystal L. Danner, Peter Larsen, Joshua Donkor, Jessica I. Johnston, Douglas Rozendaal
article en
3 citations

Abstract

We investigated whether a commercial bi-level positive airway pressure (BPAP) device, would improve peripheral oxygen saturation (SpO<sub>2</sub>) during recreational aviation up to 12,500 feet without supplemental oxygen. Ten adults with recreational flight experience (age:47 ± 14; female = 5) completed a standardized flight profile in an unpressurised aircraft, involving randomized crossover design at 8,000 feet and 12,500 feet with BPAP or control. SpO<sub>2</sub>, middle cerebral artery velocity (MCAv), heart rate (HR), respiratory rate (RR), and relative tidal volume (TV) index were measured continuously. Psychomotor vigilance test (3-min) assessed reaction time halfway through taxi and altitude stages. Altitude significantly (p < 0.05) decreased mean SpO<sub>2</sub>, MCAv, and RR, and increased TV index and HR. There was no effect of altitude (p > 0.05) on reaction time. BPAP increased mean SpO<sub>2</sub> at 8,000 feet [Control: 92 ± 1%; BPAP: 94 ± 2%; mean difference (MD) = 2 ± 2%; p = 0.002] and 12,500 feet [Control: 86 ± 4%; BPAP: 89 ± 4%; MD = 2 ± 3%; p = 0.013]. BPAP lowered MCAv at 8,000 feet [Control: 53 ± 10 cm/s; BPAP: 50 ± 9 cm/s; MD = -3 ± 2 cm/s; p = 0.001] and 12,500 feet [Control: 52 ± 10 cm/s; BPAP: 50 ± 8 cm/s; MD = -2 ± 3 cm/s; p = 0.041]. BPAP increased TV index at 8,000 feet (Control: 6.6 ± 1.3; BPAP:8.1 ± 1.8; MD = 1.9 ± 0.8; p < 0.001) but not 12,500 feet, without effect on RR or reaction time. This study provides preliminary results that BPAP may improve mean SpO<sub>2</sub> for recreational aviators up to 12,500 feet without supplemental oxygen.

Physiological ReportsVol. 13(3)
Mayo Clinic (US), Mercy Medical Center (US), The University of Queensland (AU)
Openalex Percentile: Top 6%
High Altitude and Hypoxia
5.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.