The Effect of Evaporator Pressure Behavior at Start-Up Conditions of Air Conditioning Systems to Energy Consumption and Heat Transfer

The energy issue is necessary today due to the decrease in fossil energy and its impacts on the environment. It is important to use energy effectively. In the air conditioning sector, the energy consumption of air conditioners is the top energy user in buildings. The air conditioner user needs to find the best way to operate the air conditioner. In the present research, the effect of pressure behavior at start-up conditions on the energy consumption and heat transfer process is analyzed. The result shows that the pressure behavior affects the evaporator temperature, specific heat, and thermal conductivity in liquid and vapor conditions. In the first 20-second AC operation, the energy consumption of the AC compressor increases significantly before the compressor work slowly decreases at 40-second operation and remains constant at steady conditions. The negligible heat transfer at the first 20-second AC operation increases steeply for 40 seconds. The heat transfer is steady at 60 seconds of operation and above.

Authors

Institutions

Publication Details

Journal
Engineering headway
Published
2025-02-05
DOI
https://doi.org/10.4028/p-ao9che
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Evaporator Pressure Behavior at Start-Up Conditions of Air Conditioning Systems to Energy Consumption and Heat Transfer

Jeri Tangalajuk Siang, Daud Patabang
Engineering headway
Refrigeration and Air Conditioning Technologies
article

The Effect of Evaporator Pressure Behavior at Start-Up Conditions of Air Conditioning Systems to Energy Consumption and Heat Transfer

Jeri Tangalajuk Siang, Daud Patabang
article en

Abstract

The energy issue is necessary today due to the decrease in fossil energy and its impacts on the environment. It is important to use energy effectively. In the air conditioning sector, the energy consumption of air conditioners is the top energy user in buildings. The air conditioner user needs to find the best way to operate the air conditioner. In the present research, the effect of pressure behavior at start-up conditions on the energy consumption and heat transfer process is analyzed. The result shows that the pressure behavior affects the evaporator temperature, specific heat, and thermal conductivity in liquid and vapor conditions. In the first 20-second AC operation, the energy consumption of the AC compressor increases significantly before the compressor work slowly decreases at 40-second operation and remains constant at steady conditions. The negligible heat transfer at the first 20-second AC operation increases steeply for 40 seconds. The heat transfer is steady at 60 seconds of operation and above.

Engineering headwayVol. 18
Tadulako University (ID), Universitas Atma Jaya Makassar (ID)
Openalex Percentile: Top 98%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.