Effect of OSEM Reconstruction Iteration Number and Monte Carlo Collimator Modeling on 166Ho Activity Quantification in SPECT/CT

Background: Accurate reconstruction and quantification in the post-therapy SPECT/CT imaging of 166Ho microspheres for hepatic malignancies is crucial for treatment evaluation. This present study aimed to explore the impact of the OSEM reconstruction parameters on SPECT/CT image features for dose distribution determination, using Hybrid Recon™ (Hermes Medical Solutions AB) and full Monte Carlo (MC) collimator modeling. Methods: Image quality and activity quantification were assessed through two acquisitions of the Jaszczak phantom using a Siemens Symbia Intevo Bold SPECT/CT system. The datasets were reconstructed using the OSEM method, with variations in the number of iterations for 15 and 8 subsets, both with and without full MC collimator modeling. Contrast recovery coefficient (QH), coefficient of variation (CV), contrast-to-noise ratio (CNR), calibration factor (CF), and activity recovery coefficient (ARC) were calculated and used to evaluate image quality and activity quantification. Results: Reconstructions with 5 iterations and 15 subsets, as well as 10 iterations and 8 subsets, were selected as the most suitable for 166Ho imaging, as they provided higher QH and ARCs. Incorporating full MC collimator modeling in both reconstructions led to significant improvements in image quality and activity recovery. The CFs remained consistent for a fixed value of 15 and 8 subsets, with values of (14.9 ± 0.5) cps/MBq and (14.6 ± 0.5) cps/MBq, respectively. However, when applying full collimator modeling, the CF values decreased to a range between 10.9 and 12.1 cps/MBq. Conclusions: For 166Ho SPECT/CT imaging, OSEM (with either 5 iterations and 15 subsets or 10 iterations and 8 subsets) combined with full MC collimator modeling yielded superior image quality and quantification results.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-02-05
DOI
https://doi.org/10.3390/app15031589
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of OSEM Reconstruction Iteration Number and Monte Carlo Collimator Modeling on 166Ho Activity Quantification in SPECT/CT

Vera Antunes, João Santos, Rita Albergueiro
1 citations
Applied Sciences
Medical Imaging Techniques and Applications
1.36
article

Effect of OSEM Reconstruction Iteration Number and Monte Carlo Collimator Modeling on 166Ho Activity Quantification in SPECT/CT

Vera Antunes, João Santos, Rita Albergueiro
article en
1 citations

Abstract

Background: Accurate reconstruction and quantification in the post-therapy SPECT/CT imaging of 166Ho microspheres for hepatic malignancies is crucial for treatment evaluation. This present study aimed to explore the impact of the OSEM reconstruction parameters on SPECT/CT image features for dose distribution determination, using Hybrid Recon™ (Hermes Medical Solutions AB) and full Monte Carlo (MC) collimator modeling. Methods: Image quality and activity quantification were assessed through two acquisitions of the Jaszczak phantom using a Siemens Symbia Intevo Bold SPECT/CT system. The datasets were reconstructed using the OSEM method, with variations in the number of iterations for 15 and 8 subsets, both with and without full MC collimator modeling. Contrast recovery coefficient (QH), coefficient of variation (CV), contrast-to-noise ratio (CNR), calibration factor (CF), and activity recovery coefficient (ARC) were calculated and used to evaluate image quality and activity quantification. Results: Reconstructions with 5 iterations and 15 subsets, as well as 10 iterations and 8 subsets, were selected as the most suitable for 166Ho imaging, as they provided higher QH and ARCs. Incorporating full MC collimator modeling in both reconstructions led to significant improvements in image quality and activity recovery. The CFs remained consistent for a fixed value of 15 and 8 subsets, with values of (14.9 ± 0.5) cps/MBq and (14.6 ± 0.5) cps/MBq, respectively. However, when applying full collimator modeling, the CF values decreased to a range between 10.9 and 12.1 cps/MBq. Conclusions: For 166Ho SPECT/CT imaging, OSEM (with either 5 iterations and 15 subsets or 10 iterations and 8 subsets) combined with full MC collimator modeling yielded superior image quality and quantification results.

Applied SciencesVol. 15(3)
Universidade do Porto (PT), Hospital de São João (PT), Instituto Português de Oncologia Francisco Gentil (PT), IPO Porto (PT), Hospital de Santo António (PT)
Openalex Percentile: Top 24%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.