Study on the LES of Premixed Gas Flame Dynamics in a Weak Confinement Structure: The Influence of Continuous Obstacle Plates

The layout of equipment and structures in underground utility tunnels has a significant impact on the safety of spaces. In this paper, experimental and simulation methods are combined to investigate the detonation characteristics of propane(C3H8)-air mixtures. By placing continuous obstacle plate at different positions within a pipeline, we examine the flame behavior, pressure, and flow field during the detonation process. The findings reveal that continuous obstacles create greater disturbances than single obstacles. When continuous obstacles are placed 500 mm and 800 mm from the ignition point, a secondary reignition phenomenon occurs; however, there is little difference in the time it takes for the flame front to reach the pipe’s outlet. Additionally, when continuous obstacles are positioned 200 mm and 800 mm from the ignition point, the detonation reaction weakens, with pressure peak reductions of 8.57% and 3.98% compared to the case with three single obstacles, and the maximum flame area decreases by 6.60% and 2.19%. In contrast, placing obstacles at 500 mm heightens the detonation reaction, resulting in a 2.92% increase in the pressure peak and a 19.87% increase in the maximum flame area compared to the case with three single obstacles.

Institutions

Publication Details

Journal
Journal of Applied Fluid Mechanics
Published
2025-02-05
DOI
https://doi.org/10.47176/jafm.18.4.2980
Primary Topic
Combustion and flame dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the LES of Premixed Gas Flame Dynamics in a Weak Confinement Structure: The Influence of Continuous Obstacle Plates

Journal of Applied Fluid Mechanics
Combustion and flame dynamics
article

Study on the LES of Premixed Gas Flame Dynamics in a Weak Confinement Structure: The Influence of Continuous Obstacle Plates

article en

Abstract

The layout of equipment and structures in underground utility tunnels has a significant impact on the safety of spaces. In this paper, experimental and simulation methods are combined to investigate the detonation characteristics of propane(C3H8)-air mixtures. By placing continuous obstacle plate at different positions within a pipeline, we examine the flame behavior, pressure, and flow field during the detonation process. The findings reveal that continuous obstacles create greater disturbances than single obstacles. When continuous obstacles are placed 500 mm and 800 mm from the ignition point, a secondary reignition phenomenon occurs; however, there is little difference in the time it takes for the flame front to reach the pipe’s outlet. Additionally, when continuous obstacles are positioned 200 mm and 800 mm from the ignition point, the detonation reaction weakens, with pressure peak reductions of 8.57% and 3.98% compared to the case with three single obstacles, and the maximum flame area decreases by 6.60% and 2.19%. In contrast, placing obstacles at 500 mm heightens the detonation reaction, resulting in a 2.92% increase in the pressure peak and a 19.87% increase in the maximum flame area compared to the case with three single obstacles.

Journal of Applied Fluid MechanicsVol. 18(4)
Zhejiang Ocean University (CN), Zhoushan Hospital (CN)
Climate action
Openalex Percentile: Top 98%
Combustion and flame dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.