Radiation Dose Savings Associated with Personalized CT Scan Range in<sup>18</sup>F-NaF Bone PET/CT

A disadvantage of <sup>18</sup>F-NaF PET/CT compared with other types of bone scintigraphy is the additional radiation dose from the standard whole-body CT scan for lesion localization and characterization (L/C). This study investigated whether the L/C CT region can be personalized to reduce CT radiation dose, according to uptake in the PET images. <b>Methods:</b> Attenuation-corrected <sup>18</sup>F-NaF PET images were reviewed for the clinically required L/C CT range by 1 medical observer and 1 technologist observer in 25 patients with breast cancer scanned before neoadjuvant chemotherapy. For each patient, effective doses were estimated for whole-body L/C CT, personalized L/C CT, and whole-body CT for attenuation correction only. Dose savings for the personalized method incorporating both whole-body CT for attenuation correction and personalized L/C CT were expressed relative to standard whole-body L/C CT. The clinical impact of the personalized method was determined by evaluating whether lesions clinically requiring coverage had been missed from the L/C CT region. <b>Results:</b> Potential dose savings of 43%-54% were estimated for the personalized CT method, according to the observers. From the 25 patients reviewed, the medical observer did not miss any clinically significant lesions from the L/C CT region, whereas the technologist observer missed 2 clinically significant lesions of 61 suggestive lesions identified by medical observer follow-up. <b>Conclusion:</b> Mean CT dose could be reduced by around half in this patient group with personalized CT. Future work should further evaluate whether this method can be implemented in clinical practice without compromising clinical image evaluation.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine Technology
Published
2025-02-05
DOI
https://doi.org/10.2967/jnmt.124.268246
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation Dose Savings Associated with Personalized CT Scan Range in18F-NaF Bone PET/CT

Natalie Anne Bebbington, Paw Christian Holdgaard, Helle Damgaard Zacho
Journal of Nuclear Medicine Technology
Medical Imaging Techniques and Applications
article

Radiation Dose Savings Associated with Personalized CT Scan Range in18F-NaF Bone PET/CT

Natalie Anne Bebbington, Paw Christian Holdgaard, Helle Damgaard Zacho
article en

Abstract

A disadvantage of <sup>18</sup>F-NaF PET/CT compared with other types of bone scintigraphy is the additional radiation dose from the standard whole-body CT scan for lesion localization and characterization (L/C). This study investigated whether the L/C CT region can be personalized to reduce CT radiation dose, according to uptake in the PET images. <b>Methods:</b> Attenuation-corrected <sup>18</sup>F-NaF PET images were reviewed for the clinically required L/C CT range by 1 medical observer and 1 technologist observer in 25 patients with breast cancer scanned before neoadjuvant chemotherapy. For each patient, effective doses were estimated for whole-body L/C CT, personalized L/C CT, and whole-body CT for attenuation correction only. Dose savings for the personalized method incorporating both whole-body CT for attenuation correction and personalized L/C CT were expressed relative to standard whole-body L/C CT. The clinical impact of the personalized method was determined by evaluating whether lesions clinically requiring coverage had been missed from the L/C CT region. <b>Results:</b> Potential dose savings of 43%-54% were estimated for the personalized CT method, according to the observers. From the 25 patients reviewed, the medical observer did not miss any clinically significant lesions from the L/C CT region, whereas the technologist observer missed 2 clinically significant lesions of 61 suggestive lesions identified by medical observer follow-up. <b>Conclusion:</b> Mean CT dose could be reduced by around half in this patient group with personalized CT. Future work should further evaluate whether this method can be implemented in clinical practice without compromising clinical image evaluation.

Journal of Nuclear Medicine TechnologyVol. 53(1)
Siemens (Denmark) (DK), Lillebaelt Hospital (DK), Aalborg University (DK)
Openalex Percentile: Top 97%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Radiation Dose Savings Associated with Personalized CT Scan Range in<sup>18</sup>F-NaF Bone PET/CT — Natalie Anne Bebbington, Paw Christian Holdgaard, et al. · Journal of Nuclear Medicine Technology (2025) | TGRS Research Map | TGRS