Applicability of a computer retinal model for scale-dependent investigation of legibility problems

Selecting an appropriate typeface is crucial in typography, web design, and other applications where text readability is essential. A key concept of this topic is legibility, the quality that shows how easy it is to recognize the letters of a particular font set. Previous works have measured legibility by human experiments, which has several limitations; for example, the methodology and circumstances were not entirely uniform, and the results may be distorted by the fatigue of the test subjects. This paper presents a new method using self-developed software to substitute human measurements in legibility testing. The software simulates the human retina's distortion effects (direction-dependent acuity) on test images of the assessed font's characters. Then, its output is analyzed using optical character recognition software. By integrating these techniques, we model the optical, biological, and cognitive steps of human character recognition as well. Although the simulation is imperfect, the software can perform significantly more measurements than human experiments with higher uniformity and give reproducible legibility information about significantly more fonts in various circumstances. In addition to the two scaling methods used in the literature (x-height, font-height), the tests are also performed with two other self-developed scaling methods, which provide a fairer comparison in the case of non-standard character types. This paper contains the legibility measurement results for 22 fonts under various simulated scenarios. The derived font ranking aligns closely with findings from prior human-based studies, demonstrating the robustness and reliability of the proposed method. Moreover, this approach provides valuable insights into font legibility across a broader spectrum of use cases, highlighting its potential for practical applications in typography and design.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2025-02-01
DOI
https://doi.org/10.1016/j.heliyon.2025.e42484
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applicability of a computer retinal model for scale-dependent investigation of legibility problems

Gábor Dömötör, András Horváth
Heliyon
Retinal Imaging and Analysis
article

Applicability of a computer retinal model for scale-dependent investigation of legibility problems

Gábor Dömötör, András Horváth
article en

Abstract

Selecting an appropriate typeface is crucial in typography, web design, and other applications where text readability is essential. A key concept of this topic is legibility, the quality that shows how easy it is to recognize the letters of a particular font set. Previous works have measured legibility by human experiments, which has several limitations; for example, the methodology and circumstances were not entirely uniform, and the results may be distorted by the fatigue of the test subjects. This paper presents a new method using self-developed software to substitute human measurements in legibility testing. The software simulates the human retina's distortion effects (direction-dependent acuity) on test images of the assessed font's characters. Then, its output is analyzed using optical character recognition software. By integrating these techniques, we model the optical, biological, and cognitive steps of human character recognition as well. Although the simulation is imperfect, the software can perform significantly more measurements than human experiments with higher uniformity and give reproducible legibility information about significantly more fonts in various circumstances. In addition to the two scaling methods used in the literature (x-height, font-height), the tests are also performed with two other self-developed scaling methods, which provide a fairer comparison in the case of non-standard character types. This paper contains the legibility measurement results for 22 fonts under various simulated scenarios. The derived font ranking aligns closely with findings from prior human-based studies, demonstrating the robustness and reliability of the proposed method. Moreover, this approach provides valuable insights into font legibility across a broader spectrum of use cases, highlighting its potential for practical applications in typography and design.

HeliyonVol. 11(4)
Széchenyi István University (HU)
Innovációs és Technológiai Minisztérium
Openalex Percentile: Top 97%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.