Scale correction in submicron computed tomography with a submillimeter field of view

Advances in micro-manufacturing and materials science create a demand for dimensional measurements using computed tomography with sub-micrometer resolution (submicron CT). Correction of the scale of CT data is essential for this task, but existing tools, which are used in CT modalities with lower resolutions, are often not suitable for submicron CT. The following study adapts scale correction to submicron CT using a miniature reference object with two ruby balls, which fits into a field of view with a sub-millimeter diameter and features a calibrated ball center-to-center distance of approximately 450 μm. CT data of the reference object were analyzed to determine a scale correction factor, which was applied to measurements of two additional reference objects of a similar scale and composition. The average bias of measurements for one of the objects was reduced from 3.35 μm to 0.26 μm, and the measurement uncertainty was lowered from 3.4 μm to 1.2 μm. Similar results were also achieved for the second object. The extended scan time of the reference object and the potential for sample drift, which are both typical for submicron CT, were mitigated by angular undersampling. Finally, a complementary scale correction approach is demonstrated using projection data of the reference object. This approach avoids tomographic artifacts caused by very radio-opaque objects, and it is practical for applications that utilize lower-energy X-rays. • Demands for high-resolution metrology stimulate development in computed tomography. • Submicron tomography presents unique challenges for scale correction. • Access to small-scale calibrated reference objects facilitates submicron metrology. • Scale correction in sub-micrometer resolution CT scans is feasible and practical.

Authors

Institutions

Publication Details

Journal
Tomography of Materials and Structures
Published
2025-02-05
DOI
https://doi.org/10.1016/j.tmater.2025.100054
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scale correction in submicron computed tomography with a submillimeter field of view

Jakub Šalplachta, Marek Zemek, Robert Schmitt, Jozef Kaiser et al.
Tomography of Materials and Structures
Medical Imaging Techniques and Applications
article

Scale correction in submicron computed tomography with a submillimeter field of view

Jakub Šalplachta, Marek Zemek, Robert Schmitt, Jozef Kaiser, Tomáš Zikmund, Pavel Blažek, Michal Petřík
article en

Abstract

Advances in micro-manufacturing and materials science create a demand for dimensional measurements using computed tomography with sub-micrometer resolution (submicron CT). Correction of the scale of CT data is essential for this task, but existing tools, which are used in CT modalities with lower resolutions, are often not suitable for submicron CT. The following study adapts scale correction to submicron CT using a miniature reference object with two ruby balls, which fits into a field of view with a sub-millimeter diameter and features a calibrated ball center-to-center distance of approximately 450 μm. CT data of the reference object were analyzed to determine a scale correction factor, which was applied to measurements of two additional reference objects of a similar scale and composition. The average bias of measurements for one of the objects was reduced from 3.35 μm to 0.26 μm, and the measurement uncertainty was lowered from 3.4 μm to 1.2 μm. Similar results were also achieved for the second object. The extended scan time of the reference object and the potential for sample drift, which are both typical for submicron CT, were mitigated by angular undersampling. Finally, a complementary scale correction approach is demonstrated using projection data of the reference object. This approach avoids tomographic artifacts caused by very radio-opaque objects, and it is practical for applications that utilize lower-energy X-rays. • Demands for high-resolution metrology stimulate development in computed tomography. • Submicron tomography presents unique challenges for scale correction. • Access to small-scale calibrated reference objects facilitates submicron metrology. • Scale correction in sub-micrometer resolution CT scans is feasible and practical.

Tomography of Materials and StructuresVol. 7
Central European Institute of Technology (CZ), Fraunhofer Institute for Production Technology IPT (DE), Vitkovice - Research and Development (Czechia) (CZ), Central European Institute of Technology (AT), RWTH Aachen University (DE)
Ministerstvo Školství, Mládeže a Tělovýchovy, Vysoké Učení Technické v Brně
Openalex Percentile: Top 97%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.