Determination of defect size for composites using derivative images in pulse thermography

Pulse thermography is a reliable method for detecting defects in composites with advantages of full field, non-contact and easy operation. However, the size determination of subsurface defects with low width-to-depth ratios using pulsed thermography is a challenging task due to the blurred defect edges in infrared thermal images caused by lateral heat diffusion. The present study explores the ability of time derivative images of infrared thermography to predict defect size. 2D thermal conduction of pulse thermography based on the virtual heat source method was analyzed to compare the temperature profile and derivative profile of defects along the diameter direction, and a size prediction method based on the derivative profile is proposed. The feasibility of the proposed method was evaluated by measuring the dimensions of the flat-bottomed holes in the composite panels. The experimental results demonstrated that the size inversion method based on derivative images brings an improvement in measuring accuracy for defects. Additionally, the influences of cooling time, defect depth, defect size and thermal properties of the material on the measurement of defect dimension are also discussed.

Authors

Institutions

Publication Details

Published
2025-02-05
DOI
https://doi.org/10.1117/12.3055677
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of defect size for composites using derivative images in pulse thermography

Yanjie Wei, Yao Xiao, Xiaohui Gu, Jiashuo Lu
Thermography and Photoacoustic Techniques
article

Determination of defect size for composites using derivative images in pulse thermography

Yanjie Wei, Yao Xiao, Xiaohui Gu, Jiashuo Lu
article en

Abstract

Pulse thermography is a reliable method for detecting defects in composites with advantages of full field, non-contact and easy operation. However, the size determination of subsurface defects with low width-to-depth ratios using pulsed thermography is a challenging task due to the blurred defect edges in infrared thermal images caused by lateral heat diffusion. The present study explores the ability of time derivative images of infrared thermography to predict defect size. 2D thermal conduction of pulse thermography based on the virtual heat source method was analyzed to compare the temperature profile and derivative profile of defects along the diameter direction, and a size prediction method based on the derivative profile is proposed. The feasibility of the proposed method was evaluated by measuring the dimensions of the flat-bottomed holes in the composite panels. The experimental results demonstrated that the size inversion method based on derivative images brings an improvement in measuring accuracy for defects. Additionally, the influences of cooling time, defect depth, defect size and thermal properties of the material on the measurement of defect dimension are also discussed.

Shijiazhuang Tiedao University (CN)
Openalex Percentile: Top 98%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of defect size for composites using derivative images in pulse thermography — Yanjie Wei, Yao Xiao, et al. · (2025) | TGRS Research Map | TGRS