Myoelectric Prosthetic Hand with Adjustable Tightening Socket for Varied Residual Limb Shapes*

The prosthetic socket serves as an interface between the body and the machine. If the socket is not well-fitted to the residual limb, pain can occur. The shape of the residual limb changes over time as surgical scars stabilize or the patient’s body weight fluctuates. A socket with a cutout on the side can be tightened from the outside to adjust its circumference and accommodate these changes. However, when the circumference of the rigid socket is adjusted to fit, soft skin can become trapped due to friction between the skin and the socket. This phenomenon causes pain due to pinching. Consequently, this mechanism cannot be used for myoelectric prosthetic hands, where direct contact between the socket and the skin is necessary. In this study, we developed a socket with a variable circumference that suppresses skin pinching. We applied it to participants with different residual limb shapes. A Box and Block Test (BBT) was performed using two types of sockets. The first used a conventional socket designed to fit their residual limb shape. The second used the proposed socket, which was designed to fit the residual limb’s shape of one out of two participants and adapted to the residual limb’s changing shape. The results of the BBT showed not much difference in the number of blocks moved between the conventional socket and the proposed socket. Therefore, the performance of the proposed socket was comparable to that of conventional sockets and could be applied to different residual limbs. In other words, the proposed socket was shown to adapt to changes in the residual limb without causing pain. Sockets with the proposed functionality could be used in a variety of bio-interfaces, allowing for flexible connections between the body and machines.

Authors

Institutions

Publication Details

Published
2024-11-20
DOI
https://doi.org/10.1109/cbs61689.2024.10860341
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Myoelectric Prosthetic Hand with Adjustable Tightening Socket for Varied Residual Limb Shapes*

Yusuke Yamanoi, Yoshiko Yabuki, Yong Xu, Xiaobei Jing et al.
Muscle activation and electromyography studies
article

Myoelectric Prosthetic Hand with Adjustable Tightening Socket for Varied Residual Limb Shapes*

Yusuke Yamanoi, Yoshiko Yabuki, Yong Xu, Xiaobei Jing, Hiroshi Yokoi, Yuki Inoue, Y. Kuroda
article en

Abstract

The prosthetic socket serves as an interface between the body and the machine. If the socket is not well-fitted to the residual limb, pain can occur. The shape of the residual limb changes over time as surgical scars stabilize or the patient’s body weight fluctuates. A socket with a cutout on the side can be tightened from the outside to adjust its circumference and accommodate these changes. However, when the circumference of the rigid socket is adjusted to fit, soft skin can become trapped due to friction between the skin and the socket. This phenomenon causes pain due to pinching. Consequently, this mechanism cannot be used for myoelectric prosthetic hands, where direct contact between the socket and the skin is necessary. In this study, we developed a socket with a variable circumference that suppresses skin pinching. We applied it to participants with different residual limb shapes. A Box and Block Test (BBT) was performed using two types of sockets. The first used a conventional socket designed to fit their residual limb shape. The second used the proposed socket, which was designed to fit the residual limb’s shape of one out of two participants and adapted to the residual limb’s changing shape. The results of the BBT showed not much difference in the number of blocks moved between the conventional socket and the proposed socket. Therefore, the performance of the proposed socket was comparable to that of conventional sockets and could be applied to different residual limbs. In other words, the proposed socket was shown to adapt to changes in the residual limb without causing pain. Sockets with the proposed functionality could be used in a variety of bio-interfaces, allowing for flexible connections between the body and machines.

Tokyo University of Science (JP), Chinese Academy of Sciences (CN), University of Electro-Communications (JP), Institute of Art (PL), Shenzhen Institutes of Advanced Technology (CN)
Ministry of Health
Zero hunger
Openalex Percentile: Top 76%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.