An Optimized Field Programmable Gate Array Based Noise Reduction Techniques for Fetal Electrocardiogram Signal Processing

Analyzing fetal electrocardiogram (FECG) signals is essential for identifying fetal cardiac disorders early on, although noise interference is still a problem. Conventional signal processing techniques can produce conflicting findings. With an emphasis on three important noise reduction methods the Kalman Filter, Discrete wavelet transform, and Finite impulse response this study evaluates the performance of the PYNQZ2 and NEXYS A 7 Field Programmable Gate Array (FPGA) boards in real-time FECG signal monitoring. With a mean squared error of 0.58% and a signal-to-noise ratio of 31.1 dB, the Kalman Filter fared better than the other filters, especially when it came to lowering dynamic noise in real-time applications. Furthermore, the PYNQ Z2 was outperformed by the NEXYS A7 board at processing FECG signals efficiently. effectively. By providing insights into the best noise reduction strategies and improving the accuracy of FECG monitoring in biomedical applications, this comparative analysis advances FPGA-based signal processing systems.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/iciics63763.2024.10860052
Primary Topic
Blind Source Separation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Optimized Field Programmable Gate Array Based Noise Reduction Techniques for Fetal Electrocardiogram Signal Processing

Rabab Al-Zaidi, S. Sowmya, Deepa Jose, Mahalingam Balasubramanian et al.
Blind Source Separation Techniques
article

An Optimized Field Programmable Gate Array Based Noise Reduction Techniques for Fetal Electrocardiogram Signal Processing

Rabab Al-Zaidi, S. Sowmya, Deepa Jose, Mahalingam Balasubramanian, L. B., K Aadhavan
article en

Abstract

Analyzing fetal electrocardiogram (FECG) signals is essential for identifying fetal cardiac disorders early on, although noise interference is still a problem. Conventional signal processing techniques can produce conflicting findings. With an emphasis on three important noise reduction methods the Kalman Filter, Discrete wavelet transform, and Finite impulse response this study evaluates the performance of the PYNQZ2 and NEXYS A 7 Field Programmable Gate Array (FPGA) boards in real-time FECG signal monitoring. With a mean squared error of 0.58% and a signal-to-noise ratio of 31.1 dB, the Kalman Filter fared better than the other filters, especially when it came to lowering dynamic noise in real-time applications. Furthermore, the PYNQ Z2 was outperformed by the NEXYS A7 board at processing FECG signals efficiently. effectively. By providing insights into the best noise reduction strategies and improving the accuracy of FECG monitoring in biomedical applications, this comparative analysis advances FPGA-based signal processing systems.

University of Salford (GB)
Affordable and clean energy
Openalex Percentile: Top 70%
Blind Source Separation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.