Real-Time Myoelectric-Based Neural-Drive Decoding for Concurrent and Continuous Control of Robotic Finger Forces

Neural or muscular injuries, such as due to amputation, spinal cord injury, and stroke, can affect hand functions, profoundly impacting independent living. This has motivated the advancement of cutting-edge assistive robotic hands. However, unintuitive myoelectric control of these devices remains challenging, which limits the clinical translation of these devices. Accordingly, we developed a robust motor-intent decoding approach to continuously predict the intended fingertip forces of single and multiple fingers in real time. We used population motor neuron discharge activities (i.e., neural drive from brain to spinal cord) decoded from a high-density surface electromyogram (HD-sEMG) signals as the control signals instead of the conventional global sEMG features. To enable real-time neural-drive prediction, we employed a convolutional neural network model to establish the mapping from global HD-sEMG features to finger-specific neural-drive signals, which were then employed for continuous and real-time control of three prosthetic fingers (index, middle, and ring). As a result, the neural-drive-based approach can decode the motor intent of single-finger and multifinger forces with significantly lower force estimation errors than that obtained using the global HD-sEMG-amplitude approach. Besides, the force prediction accuracy was consistent over time and demonstrated strong robustness to signal interference. Our network-based decoder can also achieve better finger isolation with minimal forces predicted in unintended fingers. Our work demonstrates that the accurate and robust finger force control could be achieved through this new decoding approach. The outcomes offer an efficient intent prediction approach that allows users to have intuitive control of prosthetic fingertip forces in a dexterous way.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Human-Machine Systems
Published
2025-02-05
DOI
https://doi.org/10.1109/thms.2025.3532209
Citations
8
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
5.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Myoelectric-Based Neural-Drive Decoding for Concurrent and Continuous Control of Robotic Finger Forces

Derek G. Kamper, Long Meng, Xiaogang Hu, Luis Vargas
8 citations
IEEE Transactions on Human-Machine Systems
Muscle activation and electromyography studies
5.39
article

Real-Time Myoelectric-Based Neural-Drive Decoding for Concurrent and Continuous Control of Robotic Finger Forces

Derek G. Kamper, Long Meng, Xiaogang Hu, Luis Vargas
article en
8 citations

Abstract

Neural or muscular injuries, such as due to amputation, spinal cord injury, and stroke, can affect hand functions, profoundly impacting independent living. This has motivated the advancement of cutting-edge assistive robotic hands. However, unintuitive myoelectric control of these devices remains challenging, which limits the clinical translation of these devices. Accordingly, we developed a robust motor-intent decoding approach to continuously predict the intended fingertip forces of single and multiple fingers in real time. We used population motor neuron discharge activities (i.e., neural drive from brain to spinal cord) decoded from a high-density surface electromyogram (HD-sEMG) signals as the control signals instead of the conventional global sEMG features. To enable real-time neural-drive prediction, we employed a convolutional neural network model to establish the mapping from global HD-sEMG features to finger-specific neural-drive signals, which were then employed for continuous and real-time control of three prosthetic fingers (index, middle, and ring). As a result, the neural-drive-based approach can decode the motor intent of single-finger and multifinger forces with significantly lower force estimation errors than that obtained using the global HD-sEMG-amplitude approach. Besides, the force prediction accuracy was consistent over time and demonstrated strong robustness to signal interference. Our network-based decoder can also achieve better finger isolation with minimal forces predicted in unintended fingers. Our work demonstrates that the accurate and robust finger force control could be achieved through this new decoding approach. The outcomes offer an efficient intent prediction approach that allows users to have intuitive control of prosthetic fingertip forces in a dexterous way.

IEEE Transactions on Human-Machine SystemsVol. 55(2)
University of North Carolina at Chapel Hill (US), Pennsylvania State University (US)
National Science Foundation, U.S. Department of Defense
Openalex Percentile: Top 5%
Muscle activation and electromyography studies
5.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.