Risk Assessment of Outdoor Micron Particulate Matters Inhaled in the Respiratory System of a Standing Mannequin in a Room Ventilated by a Wind Catcher

Background and Objective:In this study the potential of inhaled micro particles in the respiratory system of a mannequin standing in the middle of a room ventilated by a wind catcher was assessed. Methods:The realistic model of a nasal route up to the nasopharynx was obtained from Computed tomography (CT) scan images, and then attached to the nostrils of a standing mannequin.The mannequin was positioned in the middle of a room ventilated by an optimum wind catcher.Micro particles ranging from 1 m to 10 m were released from the wind catcher opening with the same velocity as the air fluid flow through a UDF and the inhaled particles were evaluated. Results:The results show that the maximum and minimum inhaled particle percentage belong to the particles with 1-m and 5-m diameters with the value of 0.0164 and 0.0136, respectively.Also, the aspiration fraction for these particles is 82 and 68 percent.The minimum and maximum percentage of inhaled particles passing the nasopharynx and going out of the nasal route are 88.35 and 71.50 percent that are associated with 1-m and 10-m particles. Conclusion:Based on the obtained results and according to the number of particles delivered to the outlet of the nasal cavity, the most detrimental particles to the respiratory system in the order are: 1, 2 , 2. 5, 3, 4, 7, 9, 6, 8, 5, and 10.This order according to the mass of particles delivered is: 10, 9, 8, 7, 6, 5, 4, 3, 2.5, 2, and 1.The results of this study provide the required data for specialists to evaluate inhalation toxicology and implement necessary measures regarding wind catchers.

Authors

Publication Details

Journal
International Journal of Clinical Studies and Medical Case Reports
Published
2025-02-05
DOI
https://doi.org/10.46998/ijcmcr.2025.49.001218
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Risk Assessment of Outdoor Micron Particulate Matters Inhaled in the Respiratory System of a Standing Mannequin in a Room Ventilated by a Wind Catcher

Farhad Zare
International Journal of Clinical Studies and Medical Case Reports
Air Quality and Health Impacts
article

Risk Assessment of Outdoor Micron Particulate Matters Inhaled in the Respiratory System of a Standing Mannequin in a Room Ventilated by a Wind Catcher

Farhad Zare
article en

Abstract

Background and Objective:In this study the potential of inhaled micro particles in the respiratory system of a mannequin standing in the middle of a room ventilated by a wind catcher was assessed. Methods:The realistic model of a nasal route up to the nasopharynx was obtained from Computed tomography (CT) scan images, and then attached to the nostrils of a standing mannequin.The mannequin was positioned in the middle of a room ventilated by an optimum wind catcher.Micro particles ranging from 1 m to 10 m were released from the wind catcher opening with the same velocity as the air fluid flow through a UDF and the inhaled particles were evaluated. Results:The results show that the maximum and minimum inhaled particle percentage belong to the particles with 1-m and 5-m diameters with the value of 0.0164 and 0.0136, respectively.Also, the aspiration fraction for these particles is 82 and 68 percent.The minimum and maximum percentage of inhaled particles passing the nasopharynx and going out of the nasal route are 88.35 and 71.50 percent that are associated with 1-m and 10-m particles. Conclusion:Based on the obtained results and according to the number of particles delivered to the outlet of the nasal cavity, the most detrimental particles to the respiratory system in the order are: 1, 2 , 2. 5, 3, 4, 7, 9, 6, 8, 5, and 10.This order according to the mass of particles delivered is: 10, 9, 8, 7, 6, 5, 4, 3, 2.5, 2, and 1.The results of this study provide the required data for specialists to evaluate inhalation toxicology and implement necessary measures regarding wind catchers.

International Journal of Clinical Studies and Medical Case ReportsVol. 49(4)
Openalex Percentile: Top 98%
Air Quality and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Risk Assessment of Outdoor Micron Particulate Matters Inhaled in the Respiratory System of a Standing Mannequin in a Room Ventilated by a Wind Catcher — Farhad Zare · International Journal of Clinical Studies and Medical Case Reports (2025) | TGRS Research Map | TGRS