Analisis Distribusi Dosis Pada Terapi Alpha dengan Teknik Pencil Beam Scanning Pada Tumor Kraniofaringioma Menggunakan Software MCNP6

This study was conducted with simulation modeling on alpha therapy for the treatment of craniopharyngioma tumors using the reference head and neck phantom geometry from Lazarine (2006), which was equipped with spherical target cell geometry. The target cell geometry with a radius of 1.05 cm contains 27 partitions located at the base of the brain close to the spine. This simulation was performed using pencil beam scanning which has a beam size of 0.35 cm and was irradiated from the left direction as far as 25 cm from the skin surface by giving 5 variations of energy ranges 425, 430, 440, 445 and 450 MeV. The results of the simulation obtained an average absorbed dose of (1.30 ± 0.01) x 10-9 Gy/α with an isodosis rate of 62%. In addition, this study also takes into account the dose received by healthy cells around the tumor. The brain organ received the largest dose of (2.69 ± 0.01) x 10-13 Gy/α, when compared to the brain tumor cells received a dose of 0.021%. From the dose distribution to tumor cells, the irradiation time for craniofaringioma tumors is (13.3 ± 0.01) s with an α particle current of 1nA.

Authors

Publication Details

Journal
Jurnal Teori dan Aplikasi Fisika
Published
2025-01-26
DOI
https://doi.org/10.23960/jtaf.v13i01.436
Primary Topic
Edcuational Technology Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Distribusi Dosis Pada Terapi Alpha dengan Teknik Pencil Beam Scanning Pada Tumor Kraniofaringioma Menggunakan Software MCNP6

Riyatun Riyatun, Suharyana Suharyana, Andina Riswandari Zulhiznaniyah
Jurnal Teori dan Aplikasi Fisika
Edcuational Technology Systems
article

Analisis Distribusi Dosis Pada Terapi Alpha dengan Teknik Pencil Beam Scanning Pada Tumor Kraniofaringioma Menggunakan Software MCNP6

Riyatun Riyatun, Suharyana Suharyana, Andina Riswandari Zulhiznaniyah
article en

Abstract

This study was conducted with simulation modeling on alpha therapy for the treatment of craniopharyngioma tumors using the reference head and neck phantom geometry from Lazarine (2006), which was equipped with spherical target cell geometry. The target cell geometry with a radius of 1.05 cm contains 27 partitions located at the base of the brain close to the spine. This simulation was performed using pencil beam scanning which has a beam size of 0.35 cm and was irradiated from the left direction as far as 25 cm from the skin surface by giving 5 variations of energy ranges 425, 430, 440, 445 and 450 MeV. The results of the simulation obtained an average absorbed dose of (1.30 ± 0.01) x 10-9 Gy/α with an isodosis rate of 62%. In addition, this study also takes into account the dose received by healthy cells around the tumor. The brain organ received the largest dose of (2.69 ± 0.01) x 10-13 Gy/α, when compared to the brain tumor cells received a dose of 0.021%. From the dose distribution to tumor cells, the irradiation time for craniofaringioma tumors is (13.3 ± 0.01) s with an α particle current of 1nA.

Jurnal Teori dan Aplikasi FisikaVol. 13(01)
Openalex Percentile: Top 99%
Edcuational Technology Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.