Numerical Simulation of Fluid–Structure Interaction in Axillary Artery Venoarterial Extracorporeal Membrane Oxygenation for Heart Failure Patients
Although axillary artery venoarterial extracorporeal membrane oxygenation (VA-ECMO) has been utilized as a mechanical circulatory support for patients with end-stage heart failure (HF), there is currently insufficient evidence to support its effectiveness and safety. The objective of this study was to analyze the hemodynamic effects of axillary artery VA-ECMO. To this end, we obtained CT angiographic imaging data of the aorta from a carefully selected heart failure patient with a cardiac output of 2.1 L/min. These data were used to construct a detailed fluid-structure interaction model of the aorta. Axillary artery VA-ECMO was then simulated within this model, maintaining a constant flow rate of 3 L/min. The intra-aortic balloon counterpulsation (IABP) balloon was simulated to inflate and deflate in synchrony with the diastolic and systolic phases of the cardiac cycle. Hemodynamic effects, including left ventricular (LV) pressure afterload, vessel wall stress, perfusion of vital organs, blood flow pulsatility, and the watershed region, were calculated using fluid-structure interaction analysis. We found that axillary artery VA-ECMO delivers well-distributed, oxygen-rich blood flow but may increase left ventricular (LV) afterload and reduce cerebral blood flow. However, when combined with IABP, it unloads LV pressure and increases cerebral blood flow. Integrating axillary artery VA-ECMO with IABP can promote cardiac function recovery and improve oxygen-rich blood perfusion to the vital organs of heart failure patients.
Authors
- Xiaoyang Hong (ORCID: https://orcid.org/0000-0003-0918-6617)
- Hao-Jie Yan (ORCID: https://orcid.org/0000-0001-7666-9964)
- Sufang Shi (ORCID: https://orcid.org/0000-0002-8949-7054)
- J.-H. Zhou (ORCID: https://orcid.org/0009-0006-7788-8644)
- Shuai Yue (ORCID: https://orcid.org/0000-0003-2289-3383)
- Ran Zhang (ORCID: https://orcid.org/0000-0002-0921-078X)
- Haiming Wang (ORCID: https://orcid.org/0000-0002-3067-2612)
- Jun Li (ORCID: https://orcid.org/0000-0001-5504-9627)
- Junjie Shao (ORCID: https://orcid.org/0009-0007-5627-6945)
Institutions
- Chinese PLA General Hospital (CN)
- PLA Academy of Military Science (CN)
Publication Details
- Journal
- International Journal for Numerical Methods in Biomedical Engineering
- Published
- 2025-02-01
- DOI
- https://doi.org/10.1002/cnm.70001
- Citations
- 1
- Primary Topic
- Mechanical Circulatory Support Devices
- Type
- article
- Field-Weighted Citation Impact
- 0.67
Funders
- National Key Research and Development Program of China