Phase noise measurement by zero-crossing analysis with a double recorder setup in the radio frequency range

The phase noise of low-noise oscillators is conventionally measured by the cross-spectrum method (CSM), which has a complicated setup. We developed an alternative method called zero-crossing analysis with a double recorder setup (ZCA-DRS) that has a much simpler configuration, which we previously demonstrated to measure phase noise in the audible frequency range. In this study, we conducted experiments using ZCA-DRS to measure phase noise in the radio frequency range. A temperature-compensated crystal oscillator was used to generate a periodic signal at 27 MHz. The results demonstrated that the obtained single-sideband spectrum was almost the same as that obtained by CSM. The measurement sensitivity was limited by the jitter of the internal clock and the noise of the analog-to-digital converter. Thus, ZCA-DRS can be used as an alternative to CSM for phase noise measurement in the radio frequency range.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-02-01
DOI
https://doi.org/10.1063/5.0240020
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase noise measurement by zero-crossing analysis with a double recorder setup in the radio frequency range

Makoto Takeuchi, Haruo Saito
AIP Advances
Advanced Frequency and Time Standards
article

Phase noise measurement by zero-crossing analysis with a double recorder setup in the radio frequency range

Makoto Takeuchi, Haruo Saito
article en

Abstract

The phase noise of low-noise oscillators is conventionally measured by the cross-spectrum method (CSM), which has a complicated setup. We developed an alternative method called zero-crossing analysis with a double recorder setup (ZCA-DRS) that has a much simpler configuration, which we previously demonstrated to measure phase noise in the audible frequency range. In this study, we conducted experiments using ZCA-DRS to measure phase noise in the radio frequency range. A temperature-compensated crystal oscillator was used to generate a periodic signal at 27 MHz. The results demonstrated that the obtained single-sideband spectrum was almost the same as that obtained by CSM. The measurement sensitivity was limited by the jitter of the internal clock and the noise of the analog-to-digital converter. Thus, ZCA-DRS can be used as an alternative to CSM for phase noise measurement in the radio frequency range.

AIP AdvancesVol. 15(2)
Tokyo University of the Arts (JP), The University of Tokyo (JP)
Openalex Percentile: Top 98%
Advanced Frequency and Time Standards
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.