The Black Metal Tribometer: High-resolution measurement of normal load-indentation curves and partial slip hysteresis cycles

A new instrument has been designed for measuring frictional hysteresis cycles and normal load-indentation curves. The primary purpose of the BMT is the validation of more predictive modeling approaches for damping in friction joints. An important original feature of the BMT is its ability to measure both normal and tangential contact behavior without having to separate the samples. Special attention was paid to alignment and smooth motion in order to permit testing nominally flat-on-flat contacts in the microslip regime. Examples are shown for finely resolved, undistorted hysteresis cycles with relative tangential displacement amplitudes in the sub-micrometer range at about 50 MPa nominal normal pressure, which is maintained well over the tangential load cycle.

Authors

Institutions

Publication Details

Journal
Tribology International
Published
2025-02-05
DOI
https://doi.org/10.1016/j.triboint.2025.110560
Primary Topic
Mechanical stress and fatigue analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Black Metal Tribometer: High-resolution measurement of normal load-indentation curves and partial slip hysteresis cycles

Daniel Fochler, Malte Krack, Lukas Kohlmann, Štefan Schwarz
Tribology International
Mechanical stress and fatigue analysis
article

The Black Metal Tribometer: High-resolution measurement of normal load-indentation curves and partial slip hysteresis cycles

Daniel Fochler, Malte Krack, Lukas Kohlmann, Štefan Schwarz
article en

Abstract

A new instrument has been designed for measuring frictional hysteresis cycles and normal load-indentation curves. The primary purpose of the BMT is the validation of more predictive modeling approaches for damping in friction joints. An important original feature of the BMT is its ability to measure both normal and tangential contact behavior without having to separate the samples. Special attention was paid to alignment and smooth motion in order to permit testing nominally flat-on-flat contacts in the microslip regime. Examples are shown for finely resolved, undistorted hysteresis cycles with relative tangential displacement amplitudes in the sub-micrometer range at about 50 MPa nominal normal pressure, which is maintained well over the tangential load cycle.

Tribology InternationalVol. 206
University of Stuttgart (DE), MTU Aero Engines (Germany) (DE)
Openalex Percentile: Top 98%
Mechanical stress and fatigue analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.