On-orbit radiometric calibration of FY-3E MERSI-LL low light band (LLB) using the Moon

The Medium Resolution Spectral Imager-Low Light (MERSI-LL) on board Fengyun-3E (FY-3E) is equipped with a low-light band (LLB), marking the first achievement of low-light remote sensing capabilities for Fengyun meteorological satellites. In response to the complexity of on-orbit radiometric calibration for LLB, a calibration method using the Moon as a stable natural target was adopted. This study compiled ten active lunar observations from MERSI-LL under the operational mode from 2022 to 2024, covering phase angles from -17.3° to 5.4°. Qualitative comparisons and quantitative analyses were conducted between the satellite observations and the Robotic Lunar Observatory (ROLO) and Miller-Turner 2009 (MT2009) lunar irradiance models, validating the accuracy of the calibration data and the reliability of the calibration methods. The results indicated a phase-angle dependence of lunar irradiance, with relative differences between the ROLO and MT2009 models consistently below 2% when the phase angle exceeded 5°. Furthermore, this study corrected the influences of lunar phase and variations in the solar spectrum when applying the MT2009 model to satellite observations. The modified MT2009 model exhibited improved consistency with MERSI-LL observations, particularly at phase angles exceeding 10°. Finally, the calibration coefficients were derived by calibrating the digital number (DN) of the MERSI-LL lunar observations against the radiance simulated by the models. The ROLO model yielded the best fitting result, with R<sup>2</sup> of 0.99796, followed by the MT2009 model and the modified model, with R<sup>2</sup> values of 0.98765 and 0.9876, respectively. We found that the ROLO model is more suitable for the on-orbit radiometric calibration of satellites compared to the MT2009 model. Meanwhile, the total uncertainty of the calibration is approximately 5.78%. This study provides a validated methodology for lunar-based calibration applicable to other low-light remote sensing systems and a reference for the optimization of lunar irradiance models.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-05
DOI
https://doi.org/10.1364/oe.551275
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-orbit radiometric calibration of FY-3E MERSI-LL low light band (LLB) using the Moon

Haoran Gu, Zhengqiang Li, Xiuqing Hu, Jun Zhu et al.
Optics Express
Calibration and Measurement Techniques
article

On-orbit radiometric calibration of FY-3E MERSI-LL low light band (LLB) using the Moon

Haoran Gu, Zhengqiang Li, Xiuqing Hu, Jun Zhu, Li Li, Hanlie Xu, Enze Wen
article en

Abstract

The Medium Resolution Spectral Imager-Low Light (MERSI-LL) on board Fengyun-3E (FY-3E) is equipped with a low-light band (LLB), marking the first achievement of low-light remote sensing capabilities for Fengyun meteorological satellites. In response to the complexity of on-orbit radiometric calibration for LLB, a calibration method using the Moon as a stable natural target was adopted. This study compiled ten active lunar observations from MERSI-LL under the operational mode from 2022 to 2024, covering phase angles from -17.3° to 5.4°. Qualitative comparisons and quantitative analyses were conducted between the satellite observations and the Robotic Lunar Observatory (ROLO) and Miller-Turner 2009 (MT2009) lunar irradiance models, validating the accuracy of the calibration data and the reliability of the calibration methods. The results indicated a phase-angle dependence of lunar irradiance, with relative differences between the ROLO and MT2009 models consistently below 2% when the phase angle exceeded 5°. Furthermore, this study corrected the influences of lunar phase and variations in the solar spectrum when applying the MT2009 model to satellite observations. The modified MT2009 model exhibited improved consistency with MERSI-LL observations, particularly at phase angles exceeding 10°. Finally, the calibration coefficients were derived by calibrating the digital number (DN) of the MERSI-LL lunar observations against the radiance simulated by the models. The ROLO model yielded the best fitting result, with R<sup>2</sup> of 0.99796, followed by the MT2009 model and the modified model, with R<sup>2</sup> values of 0.98765 and 0.9876, respectively. We found that the ROLO model is more suitable for the on-orbit radiometric calibration of satellites compared to the MT2009 model. Meanwhile, the total uncertainty of the calibration is approximately 5.78%. This study provides a validated methodology for lunar-based calibration applicable to other low-light remote sensing systems and a reference for the optimization of lunar irradiance models.

Optics ExpressVol. 33(5)
Information Technology University (PK), Henan University (CN), National Influenza Center (MN)
National Natural Science Foundation of China, National Outstanding Youth Science Fund Project of National Natural Science Foundation of China
Openalex Percentile: Top 97%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.