Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line

UHV (ultra-high voltage) by instant AC transmission system is accompanied by huge reactive power transmission. When the load drops sharply, it is easy to produce serious power frequency overvoltage, which is also defined as load rejection overvoltage. This paper makes an in-depth analysis from the perspective of voltage increase caused by instantaneous load unloading, and obtains the causes and key influencing factors of load rejection overvoltage. Taking the UHV AC transmission line of a practical project as an example, the suppression effect of the suppression strategy represented by the installation of opening resistance and shunt reactor on the load rejection overvoltage is analyzed. The simulation results show that the above method has an obvious inhibitory effect on load rejection overvoltage. Based on the optimal suppression principle, the optional interval range of the opening resistance and shunt reactor parameters are designed.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-02-05
DOI
https://doi.org/10.3390/electronics14030619
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line

Yingge Wang, Rusi Chen, Yixing Ding, Dian Xu et al.
Electronics
Power Systems Fault Detection
article

Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line

Yingge Wang, Rusi Chen, Yixing Ding, Dian Xu, Haiguang Liu, Guanqun Sun, Wang Ma
article en

Abstract

UHV (ultra-high voltage) by instant AC transmission system is accompanied by huge reactive power transmission. When the load drops sharply, it is easy to produce serious power frequency overvoltage, which is also defined as load rejection overvoltage. This paper makes an in-depth analysis from the perspective of voltage increase caused by instantaneous load unloading, and obtains the causes and key influencing factors of load rejection overvoltage. Taking the UHV AC transmission line of a practical project as an example, the suppression effect of the suppression strategy represented by the installation of opening resistance and shunt reactor on the load rejection overvoltage is analyzed. The simulation results show that the above method has an obvious inhibitory effect on load rejection overvoltage. Based on the optimal suppression principle, the optional interval range of the opening resistance and shunt reactor parameters are designed.

ElectronicsVol. 14(3)
Nanjing Tech University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 98%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.