Measurement of scattering azimuthal distribution of polarized gamma-rays in compton scattering using GAGG(Ce) scintillator

Abstract Recently, the measurement of gamma-rays polarization has increasingly become important for applications in various fields such as astrophysics and bioimaging. Accordingly, there is a growing need for high-performance polarimeters to meet these requirements. In this study, we fabricated the gamma-rays polarization detector using Gd 3 (Ga,Al) 5 O 12 (Ce) scintillator, which has high energy resolution, high amount of luminescence, and fast decay time. This detector mainly consists of scatterer and absorber, each of which use pixelated GAGG array. By using this detector, the gamma-rays polarization was measured in MeV range (6.6 MeV), and the performance as polarimeter was assessed.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-02-01
DOI
https://doi.org/10.1088/1748-0221/20/02/c02007
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of scattering azimuthal distribution of polarized gamma-rays in compton scattering using GAGG(Ce) scintillator

Mizuki Uenomachi, Moh Hamdan, Kenji Shimazoe, Y. Taira et al.
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
article

Measurement of scattering azimuthal distribution of polarized gamma-rays in compton scattering using GAGG(Ce) scintillator

Mizuki Uenomachi, Moh Hamdan, Kenji Shimazoe, Y. Taira, Riku Sato
article en

Abstract

Abstract Recently, the measurement of gamma-rays polarization has increasingly become important for applications in various fields such as astrophysics and bioimaging. Accordingly, there is a growing need for high-performance polarimeters to meet these requirements. In this study, we fabricated the gamma-rays polarization detector using Gd 3 (Ga,Al) 5 O 12 (Ce) scintillator, which has high energy resolution, high amount of luminescence, and fast decay time. This detector mainly consists of scatterer and absorber, each of which use pixelated GAGG array. By using this detector, the gamma-rays polarization was measured in MeV range (6.6 MeV), and the performance as polarimeter was assessed.

Journal of InstrumentationVol. 20(02)
Tokyo Institute of Technology (JP), National Institutes of Natural Sciences (JP), The Graduate University for Advanced Studies, SOKENDAI (JP), Institute for Molecular Science (JP), The University of Tokyo (JP)
Openalex Percentile: Top 97%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurement of scattering azimuthal distribution of polarized gamma-rays in compton scattering using GAGG(Ce) scintillator — Mizuki Uenomachi, Moh Hamdan, et al. · Journal of Instrumentation (2025) | TGRS Research Map | TGRS