Programming an Amplified and Self-Calibrated Electrochemical Biosensor with High Sensitivity, Reproducibility, and Stability for ORAOV 1 Detection

The ability to accurately detect oral cancer overexpressed 1 (ORAOV 1) offers significant potential for the noninvasive and rapid diagnosis of oral squamous cell carcinoma (OSCC). Present here is an amplified and self-calibrated electrochemical (EC) biosensor for ORAOV 1 detection. This cutting-edge EC biosensor adopts a fuel-driven DNA molecular machine to induce target recycling, thereby amplifying the signals. Meanwhile, by integrating UiO-66 with graphene oxide (GO), the resulting GO@UiO-66 nanomaterials can effectively load substantial amounts of methylene blue (MB), thereby enhancing the EC performance and dramatically improving detection sensitivity. Furthermore, a ratiometric output mode is being developed by using highly conductive GO@UiO-66/MB and silver nanoparticles (Ag NPs) as electroactive tags. By leveraging this ratiometric strategy, which incorporates a built-in self-calibration factor that effectively eliminates systematic errors, the reproducibility, stability, and accuracy of the biosensor can be significantly enhanced. Experimental results demonstrate that this newly developed EC biosensor exhibits ultrahigh sensitivity, with a detection limit as low as 0.28 aM, and a broad linear range from 0.01 fM to 1 pM. Notably, it offers greater reproducibility, stability, and anti-interference capability compared to single-signal output modes. Meanwhile, the detection of ORAOV 1 in human saliva samples has been exemplified with a satisfactory recovery rate and anti-interference capability. More importantly, it can discriminate oral cancer patients from clinical samples with high accuracy (AUC = 1). This approach provides new insights into the noninvasive and early diagnosis of OSCC in clinical applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-02-05
DOI
https://doi.org/10.1021/acs.analchem.4c05679
Citations
6
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Programming an Amplified and Self-Calibrated Electrochemical Biosensor with High Sensitivity, Reproducibility, and Stability for ORAOV 1 Detection

Minhui Chen, Jin Lin Huang, Qin Xu, Jing Li et al.
6 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
4.84
article

Programming an Amplified and Self-Calibrated Electrochemical Biosensor with High Sensitivity, Reproducibility, and Stability for ORAOV 1 Detection

Minhui Chen, Jin Lin Huang, Qin Xu, Jing Li, Yuchen Li, Wei Zhang, Qi Jiang, Di Qiu
article en
6 citations

Abstract

The ability to accurately detect oral cancer overexpressed 1 (ORAOV 1) offers significant potential for the noninvasive and rapid diagnosis of oral squamous cell carcinoma (OSCC). Present here is an amplified and self-calibrated electrochemical (EC) biosensor for ORAOV 1 detection. This cutting-edge EC biosensor adopts a fuel-driven DNA molecular machine to induce target recycling, thereby amplifying the signals. Meanwhile, by integrating UiO-66 with graphene oxide (GO), the resulting GO@UiO-66 nanomaterials can effectively load substantial amounts of methylene blue (MB), thereby enhancing the EC performance and dramatically improving detection sensitivity. Furthermore, a ratiometric output mode is being developed by using highly conductive GO@UiO-66/MB and silver nanoparticles (Ag NPs) as electroactive tags. By leveraging this ratiometric strategy, which incorporates a built-in self-calibration factor that effectively eliminates systematic errors, the reproducibility, stability, and accuracy of the biosensor can be significantly enhanced. Experimental results demonstrate that this newly developed EC biosensor exhibits ultrahigh sensitivity, with a detection limit as low as 0.28 aM, and a broad linear range from 0.01 fM to 1 pM. Notably, it offers greater reproducibility, stability, and anti-interference capability compared to single-signal output modes. Meanwhile, the detection of ORAOV 1 in human saliva samples has been exemplified with a satisfactory recovery rate and anti-interference capability. More importantly, it can discriminate oral cancer patients from clinical samples with high accuracy (AUC = 1). This approach provides new insights into the noninvasive and early diagnosis of OSCC in clinical applications.

Analytical ChemistryVol. 97(6)
Hunan University (CN), State Key Laboratory of Chemobiosensing and Chemometrics (CN), Yangzhou University (CN)
Key Project of Research and Development Plan of Hunan Province, National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Jiangsu Province, Natural Science Research of Jiangsu Higher Education Institutions of China
Openalex Percentile: Top 5%
Advanced biosensing and bioanalysis techniques
4.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.