Optimized inducer design for transporting air–water two-phase flows in centrifugal pumps: Outperforming traditional inducers

This study investigates the impact of different inducer designs on centrifugal pump performance during air–water two-phase flow pumping. A semi-open impeller with elliptical blades was tested with three configurations: no inducer, a traditional industrial inducer, and a novel optimized inducer. Experiments were conducted at a relevant rotational speed of 1450 rpm. The experimental analysis explores the performance for constant gas volume fraction, constant air flow rate, performance degradation, surging (flow instabilities), and two-phase flow regimes. High-speed cameras captured flow behavior to identify and categorize the flow regimes present during operation for each configuration. The results reveal that the industrial inducer could only provide limited performance improvements at part-load for the gas volume fraction range of 5%–6%. In contrary, the optimized inducer effectively delayed the sharp performance degradation to 7% gas volume fraction. Additionally, it provided almost constant performance near optimal flow conditions, showing a flat behavior up to 7% gas volume fraction. Performance improvements are still noticeable up to 11% air content. While the industrial inducer negatively advanced the onset of pump surging and increased its intensity, the optimized inducer strongly delays pump surging and maintains it at low intensity. The use of the industrial inducer leads to unstable curves for a wide range of flow rates for the performance with constant air flow rate at the inlet. However, the optimized inducer could improve that performance along the entire flow range, with almost no reduction near the optimal flow up to 100 L/min flow of air. The recorded flow regimes show the improved two-phase mixing and higher gas accumulation resistance when using the optimized inducer. Accordingly, the use of such an optimized inducer is highly recommended to keep robust two-phase pumping with minimal flow instabilities. the optimized inducer demonstrates remarkable effectiveness in enhancing pump performance. Based on our own experimental comparisons and findings, these improvements strongly outperform the capabilities of other traditional techniques commonly used to transport two-phase flows, including impeller modifications, tip clearance adjustments, and the use of a standard inducer. • Air–water two-phase flows were studied experimentally in a radial centrifugal pump. • The performances without, with a standard inducer, or with an optimized inducer were compared. • Performance, hysteresis, head degradation, flow regimes, and surging were considered. • The use of the optimized inducer leads to several advantages and significant improvements. • It provided performance improvements even up to 11% air content.

Authors

Publication Details

Journal
Process Safety and Environmental Protection
Published
2025-02-05
DOI
https://doi.org/10.1016/j.cherd.2025.01.039
Citations
3
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
2.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized inducer design for transporting air–water two-phase flows in centrifugal pumps: Outperforming traditional inducers

Michael Mansour, Dominique Thévenin
3 citations
Process Safety and Environmental Protection
Cavitation Phenomena in Pumps
2.59
article

Optimized inducer design for transporting air–water two-phase flows in centrifugal pumps: Outperforming traditional inducers

Michael Mansour, Dominique Thévenin
article en
3 citations

Abstract

This study investigates the impact of different inducer designs on centrifugal pump performance during air–water two-phase flow pumping. A semi-open impeller with elliptical blades was tested with three configurations: no inducer, a traditional industrial inducer, and a novel optimized inducer. Experiments were conducted at a relevant rotational speed of 1450 rpm. The experimental analysis explores the performance for constant gas volume fraction, constant air flow rate, performance degradation, surging (flow instabilities), and two-phase flow regimes. High-speed cameras captured flow behavior to identify and categorize the flow regimes present during operation for each configuration. The results reveal that the industrial inducer could only provide limited performance improvements at part-load for the gas volume fraction range of 5%–6%. In contrary, the optimized inducer effectively delayed the sharp performance degradation to 7% gas volume fraction. Additionally, it provided almost constant performance near optimal flow conditions, showing a flat behavior up to 7% gas volume fraction. Performance improvements are still noticeable up to 11% air content. While the industrial inducer negatively advanced the onset of pump surging and increased its intensity, the optimized inducer strongly delays pump surging and maintains it at low intensity. The use of the industrial inducer leads to unstable curves for a wide range of flow rates for the performance with constant air flow rate at the inlet. However, the optimized inducer could improve that performance along the entire flow range, with almost no reduction near the optimal flow up to 100 L/min flow of air. The recorded flow regimes show the improved two-phase mixing and higher gas accumulation resistance when using the optimized inducer. Accordingly, the use of such an optimized inducer is highly recommended to keep robust two-phase pumping with minimal flow instabilities. the optimized inducer demonstrates remarkable effectiveness in enhancing pump performance. Based on our own experimental comparisons and findings, these improvements strongly outperform the capabilities of other traditional techniques commonly used to transport two-phase flows, including impeller modifications, tip clearance adjustments, and the use of a standard inducer. • Air–water two-phase flows were studied experimentally in a radial centrifugal pump. • The performances without, with a standard inducer, or with an optimized inducer were compared. • Performance, hysteresis, head degradation, flow regimes, and surging were considered. • The use of the optimized inducer leads to several advantages and significant improvements. • It provided performance improvements even up to 11% air content.

Process Safety and Environmental ProtectionVol. 215
Openalex Percentile: Top 13%
Cavitation Phenomena in Pumps
2.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.