Comparison of tissue reaction in primary tracheal repair using silk, monofilament absorbable (Polyglecaprone), and multifilament absorbable (Polyglactin 910) sutures (An experimental study on New Zealand rabbits)

Surgical interventions for tracheal trauma include repairing lacerations, reducing and closing cartilage fractures, and performing end-to-end anastomosis in cases of complete transection. One of the potential long-term complications following tracheal surgery is tracheal stenosis. The inflammatory reaction depends on the suture material used, the type of tissue being sutured, and the immune system. Several factors related to the suture material that influence the inflammatory reaction include suture absorbability, the number of filaments, suture size, and tissue reactivity to the suture. This study aimed to compare the inflammatory reaction (tissue reaction) caused by various suture materials in primary tracheal repair in male New Zealand rabbits. This experimental study employed a randomized controlled trial design, conducted on male New Zealand white rabbits. The rabbits were acclimatized for seven days, followed by permuted block randomization, dividing the samples into four groups. After the inflammatory phase (7 days), tissue reactions in the surgical area were examined post-tracheal reconstruction. Data analysis was performed using SPSS software. Each group consisted of six samples, demonstrating homogeneity in terms of age (p = 0.93), preoperative weight (p = 0.87), and postoperative weight (p = 0.88). Macroscopic evaluation showed no wound dehiscence, pus, or tracheal defects caused by suture displacement. Histopathological analysis revealed a significantly different degree of inflammation (p = 0.049) between the two treatment groups. Monofilament absorbable sutures (polyglecaprone) exhibited a lower inflammatory reaction than multifilament absorbable sutures (polyglactin 910) in primary tracheal repair, with silk sutures as the control.

Authors

Institutions

Publication Details

Journal
Edelweiss Applied Science and Technology
Published
2025-02-05
DOI
https://doi.org/10.55214/25768484.v9i2.4599
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of tissue reaction in primary tracheal repair using silk, monofilament absorbable (Polyglecaprone), and multifilament absorbable (Polyglactin 910) sutures (An experimental study on New Zealand rabbits)

Marjono Dwi Wibowo, Santi Santi
Edelweiss Applied Science and Technology
Tracheal and airway disorders
article

Comparison of tissue reaction in primary tracheal repair using silk, monofilament absorbable (Polyglecaprone), and multifilament absorbable (Polyglactin 910) sutures (An experimental study on New Zealand rabbits)

Marjono Dwi Wibowo, Santi Santi
article en

Abstract

Surgical interventions for tracheal trauma include repairing lacerations, reducing and closing cartilage fractures, and performing end-to-end anastomosis in cases of complete transection. One of the potential long-term complications following tracheal surgery is tracheal stenosis. The inflammatory reaction depends on the suture material used, the type of tissue being sutured, and the immune system. Several factors related to the suture material that influence the inflammatory reaction include suture absorbability, the number of filaments, suture size, and tissue reactivity to the suture. This study aimed to compare the inflammatory reaction (tissue reaction) caused by various suture materials in primary tracheal repair in male New Zealand rabbits. This experimental study employed a randomized controlled trial design, conducted on male New Zealand white rabbits. The rabbits were acclimatized for seven days, followed by permuted block randomization, dividing the samples into four groups. After the inflammatory phase (7 days), tissue reactions in the surgical area were examined post-tracheal reconstruction. Data analysis was performed using SPSS software. Each group consisted of six samples, demonstrating homogeneity in terms of age (p = 0.93), preoperative weight (p = 0.87), and postoperative weight (p = 0.88). Macroscopic evaluation showed no wound dehiscence, pus, or tracheal defects caused by suture displacement. Histopathological analysis revealed a significantly different degree of inflammation (p = 0.049) between the two treatment groups. Monofilament absorbable sutures (polyglecaprone) exhibited a lower inflammatory reaction than multifilament absorbable sutures (polyglactin 910) in primary tracheal repair, with silk sutures as the control.

Edelweiss Applied Science and TechnologyVol. 9(2)
Universitas Airlangga (ID)
Openalex Percentile: Top 97%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of tissue reaction in primary tracheal repair using silk, monofilament absorbable (Polyglecaprone), and multifilament absorbable (Polyglactin 910) sutures (An experimental study on New Zealand rabbits) — Marjono Dwi Wibowo, Santi Santi · Edelweiss Applied Science and Technology (2025) | TGRS Research Map | TGRS