Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab

PIP-II cryomodules use a computer vision system (H-BCAMs system) to monitor the alignment of SRF cavities and focusing lenses during assembly, testing, and operation. This contribution details the integration of the H-BCAMs into the Spoke Test Cryostat (STC) at Fermilab, which is utilized for cold testing SRF cavities prior to their integration into the string assembly. Thermal and structural finite element analyses were employed to estimate the cavities’ deformations, to be validated during cold testing in the STC using H-BCAMs. Notably, this marks the first instance of H-BCAMs integration into a cryostat and operation within a cryogenic environment.

Authors

Institutions

Publication Details

Journal
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Published
2024-10-25
DOI
https://doi.org/10.18429/jacow-linac2024-mopb064
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab

Mattia Parise, Vincent Roger, Silvia Zorzetti, Donato Passarelli et al.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Particle Detector Development and Performance
article

Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab

Mattia Parise, Vincent Roger, Silvia Zorzetti, Donato Passarelli, Ambre Gonzalez–Moreau, Nitin Kumar, Fred Lewis, J. Bernardini, D. A. Dillman
article en

Abstract

PIP-II cryomodules use a computer vision system (H-BCAMs system) to monitor the alignment of SRF cavities and focusing lenses during assembly, testing, and operation. This contribution details the integration of the H-BCAMs into the Spoke Test Cryostat (STC) at Fermilab, which is utilized for cold testing SRF cavities prior to their integration into the string assembly. Thermal and structural finite element analyses were employed to estimate the cavities’ deformations, to be validated during cold testing in the STC using H-BCAMs. Notably, this marks the first instance of H-BCAMs integration into a cryostat and operation within a cryogenic environment.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Fermi National Accelerator Laboratory (US), Science and Technology Facilities Council (GB), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Sci-Tech Daresbury (GB), Institut de Recherche sur les Lois Fondamentales de l'Univers (FR)
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab — Mattia Parise, Vincent Roger, et al. · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (2024) | TGRS Research Map | TGRS