Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab
PIP-II cryomodules use a computer vision system (H-BCAMs system) to monitor the alignment of SRF cavities and focusing lenses during assembly, testing, and operation. This contribution details the integration of the H-BCAMs into the Spoke Test Cryostat (STC) at Fermilab, which is utilized for cold testing SRF cavities prior to their integration into the string assembly. Thermal and structural finite element analyses were employed to estimate the cavities’ deformations, to be validated during cold testing in the STC using H-BCAMs. Notably, this marks the first instance of H-BCAMs integration into a cryostat and operation within a cryogenic environment.
Authors
- Mattia Parise
- Vincent Roger
- Silvia Zorzetti (ORCID: https://orcid.org/0000-0002-3208-3387)
- Donato Passarelli (ORCID: https://orcid.org/0000-0003-0191-5002)
- Ambre Gonzalez–Moreau
- Nitin Kumar
- Fred Lewis
- J. Bernardini (ORCID: https://orcid.org/0000-0003-2771-0064)
- D. A. Dillman
Institutions
- Fermi National Accelerator Laboratory (US)
- Science and Technology Facilities Council (GB)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Sci-Tech Daresbury (GB)
- Institut de Recherche sur les Lois Fondamentales de l'Univers (FR)
Publication Details
- Journal
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
- Published
- 2024-10-25
- DOI
- https://doi.org/10.18429/jacow-linac2024-mopb064
- Primary Topic
- Particle Detector Development and Performance
- Type
- article
- Field-Weighted Citation Impact
- 0.00