Flow-induced corrosion of brass flowmeters used for drinking water

• Failure of flowmeters occurred primarily due to flow-induced corrosion. • Degraded regions showed zinc depletion of the brass. • Corrosion deposits consisted of copper-oxide, −chloride, and malachite. • The drinking water was slightly scale-forming and slightly corrosive. • Considering flow conditions is crucial to mitigate degradation. Traditionally, water supply components were made of dezincification-resistant brass alloys due to their relatively low cost, good forging properties, and good machinability. However, due to recent legislation on the restrictions of lead and nickel, increased use of disinfection, and a more diverse range of flow conditions, corrosion failures have become more prevalent. This work describes the failure investigations of two domestic water flowmeters made of dezincification-resistant brass type CW511L, with a difference in internal diameter. The underlying cause of failure is determined by visual inspection, microstructural analysis with scanning electron microscopy, energy-dispersive X-ray spectroscopy, and corrosion product identification using X-ray diffraction. The scales formed at less degraded regions were identified as copper-enriched corrosion products mainly consisting of metallic elements, oxygen, and chloride, with most of the scale formation being malachite. Depletion of protective scales was seen in regions with high flow, resulting in flow-induced corrosion and high material losses. Computer fluid dynamics simulations confirm that specific regions were exposed to high flow rates, resulting in failure.

Authors

Institutions

Publication Details

Journal
Engineering Failure Analysis
Published
2025-02-05
DOI
https://doi.org/10.1016/j.engfailanal.2025.109394
Citations
4
Primary Topic
Erosion and Abrasive Machining
Type
article
Field-Weighted Citation Impact
7.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow-induced corrosion of brass flowmeters used for drinking water

John Hald, Morten Stendahl Jellesen, Lotte Holmegaard, Luca Blanka Boncz et al.
4 citations
Engineering Failure Analysis
Erosion and Abrasive Machining
7.35
article

Flow-induced corrosion of brass flowmeters used for drinking water

John Hald, Morten Stendahl Jellesen, Lotte Holmegaard, Luca Blanka Boncz, Jens Lykke Sørensen
article en
4 citations

Abstract

• Failure of flowmeters occurred primarily due to flow-induced corrosion. • Degraded regions showed zinc depletion of the brass. • Corrosion deposits consisted of copper-oxide, −chloride, and malachite. • The drinking water was slightly scale-forming and slightly corrosive. • Considering flow conditions is crucial to mitigate degradation. Traditionally, water supply components were made of dezincification-resistant brass alloys due to their relatively low cost, good forging properties, and good machinability. However, due to recent legislation on the restrictions of lead and nickel, increased use of disinfection, and a more diverse range of flow conditions, corrosion failures have become more prevalent. This work describes the failure investigations of two domestic water flowmeters made of dezincification-resistant brass type CW511L, with a difference in internal diameter. The underlying cause of failure is determined by visual inspection, microstructural analysis with scanning electron microscopy, energy-dispersive X-ray spectroscopy, and corrosion product identification using X-ray diffraction. The scales formed at less degraded regions were identified as copper-enriched corrosion products mainly consisting of metallic elements, oxygen, and chloride, with most of the scale formation being malachite. Depletion of protective scales was seen in regions with high flow, resulting in flow-induced corrosion and high material losses. Computer fluid dynamics simulations confirm that specific regions were exposed to high flow rates, resulting in failure.

Engineering Failure AnalysisVol. 171
Kamchatka State University named after Vitus Bering (RU), Technical University of Denmark (DK)
Innovationsfonden
Clean water and sanitation
Openalex Percentile: Top 4%
Erosion and Abrasive Machining
7.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Flow-induced corrosion of brass flowmeters used for drinking water — John Hald, Morten Stendahl Jellesen, et al. · Engineering Failure Analysis (2025) | TGRS Research Map | TGRS