TRIBOLOGICAL TESTS Of MATERIALS FOR HIP JOINTENDOPROSTHESIS CUPS

Hip joint alloplasty completely changes the cooperation conditions of the correct biological friction pair byintroducing a cup and a head on a stem. When selecting an endoprosthesis, a choice should be made betweena rigid tribological node and a flexible biobearing that absorbs locomotion loads, which better approximatesthe conditions in a normal joint. The aim of the study is to compare and evaluate the tribological andmicromechanical parameters of selected biomaterials used for hip joint endoprosthesis cups. The conductedtests of wear resistance and determination of coefficients of friction, as well as microhardness and Young’smodulus tests, allowed us to determine which materials will be preferred for hip joint endoprosthesis cups.Based on the results of the tribological tests performed, the authors identify the most favorable tribologicalpair in the context of wear and coefficient of friction. Improving the tribological cooperation of the bearingpair used, reducing wear and generation of friction products in particular, may influence the articulationconditions of the endoprosthesis and the length of its survival in the body.

Authors

Institutions

Publication Details

Journal
Tribologia
Published
2025-02-04
DOI
https://doi.org/10.5604/01.3001.0054.9826
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TRIBOLOGICAL TESTS Of MATERIALS FOR HIP JOINTENDOPROSTHESIS CUPS

Łukasz Bojko, Paweł Pałka, Piotr Osada, Elżbieta Makowska
Tribologia
Orthopaedic implants and arthroplasty
article

TRIBOLOGICAL TESTS Of MATERIALS FOR HIP JOINTENDOPROSTHESIS CUPS

Łukasz Bojko, Paweł Pałka, Piotr Osada, Elżbieta Makowska
article en

Abstract

Hip joint alloplasty completely changes the cooperation conditions of the correct biological friction pair byintroducing a cup and a head on a stem. When selecting an endoprosthesis, a choice should be made betweena rigid tribological node and a flexible biobearing that absorbs locomotion loads, which better approximatesthe conditions in a normal joint. The aim of the study is to compare and evaluate the tribological andmicromechanical parameters of selected biomaterials used for hip joint endoprosthesis cups. The conductedtests of wear resistance and determination of coefficients of friction, as well as microhardness and Young’smodulus tests, allowed us to determine which materials will be preferred for hip joint endoprosthesis cups.Based on the results of the tribological tests performed, the authors identify the most favorable tribologicalpair in the context of wear and coefficient of friction. Improving the tribological cooperation of the bearingpair used, reducing wear and generation of friction products in particular, may influence the articulationconditions of the endoprosthesis and the length of its survival in the body.

TribologiaVol. 310(4)
AGH University of Krakow (PL)
Openalex Percentile: Top 96%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.