On the localization of the high-intensity region of simultaneous space-time foci

Simultaneous space-time focusing (SSTF) is sometimes claimed to reduce the longitudinal extent of the high-intensity region near the focus, in contradiction to the original work on this topic. Here we seek to address this confusion by using numerical and analytical methods to investigate the degree of localization of the spatio-temporal intensity of an SSTF pulse. The analytical method is found to be in excellent agreement with numerical calculations and yields, for bi-Gaussian input pulses, expressions for the three-dimensional spatio-temporal intensity profile of the SSTF pulse, and for the on-axis bandwidth, pulse duration, and pulse-front tilt (PFT) of the SSTF pulse. To provide further insight, we propose a method for determining the transverse input profile of a non-SSTF pulse with equivalent spatial focusing. We find that the longitudinal variations of the peak axial intensities of the SSTF and spatially equivalent (SE) pulses are the same, apart from a constant factor, and hence that SSTF does not constrain the region of high intensity more than a non-SSTF pulse with equivalent focusing. We demonstrate that a simplistic method for calculating the pulse intensity exaggerates the degree of intensity localization, unless the spatio-temporal couplings inherent to SSTF pulses are accounted for.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-05
DOI
https://doi.org/10.1364/oe.546012
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the localization of the high-intensity region of simultaneous space-time foci

S. M. Hooker, Bangshan Sun, Martin J. Booth, R. Walczak et al.
1 citations
Optics Express
Optical measurement and interference techniques
1.28
article

On the localization of the high-intensity region of simultaneous space-time foci

S. M. Hooker, Bangshan Sun, Martin J. Booth, R. Walczak, Emily Archer
article en
1 citations

Abstract

Simultaneous space-time focusing (SSTF) is sometimes claimed to reduce the longitudinal extent of the high-intensity region near the focus, in contradiction to the original work on this topic. Here we seek to address this confusion by using numerical and analytical methods to investigate the degree of localization of the spatio-temporal intensity of an SSTF pulse. The analytical method is found to be in excellent agreement with numerical calculations and yields, for bi-Gaussian input pulses, expressions for the three-dimensional spatio-temporal intensity profile of the SSTF pulse, and for the on-axis bandwidth, pulse duration, and pulse-front tilt (PFT) of the SSTF pulse. To provide further insight, we propose a method for determining the transverse input profile of a non-SSTF pulse with equivalent spatial focusing. We find that the longitudinal variations of the peak axial intensities of the SSTF and spatially equivalent (SE) pulses are the same, apart from a constant factor, and hence that SSTF does not constrain the region of high intensity more than a non-SSTF pulse with equivalent focusing. We demonstrate that a simplistic method for calculating the pulse intensity exaggerates the degree of intensity localization, unless the spatio-temporal couplings inherent to SSTF pulses are accounted for.

Optics ExpressVol. 33(4)
Somerville Hospital (US), University of Oxford (GB)
Engineering and Physical Sciences Research Council, Science and Technology Facilities Council
Climate action
Openalex Percentile: Top 23%
Optical measurement and interference techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On the localization of the high-intensity region of simultaneous space-time foci — S. M. Hooker, Bangshan Sun, et al. · Optics Express (2025) | TGRS Research Map | TGRS