The Effect of GO Flake Size on Field-Effect Transistor (FET)-Based Biosensor Performance for Detection of Ions and PACAP 38

The performance development of rGO-FET biosensors by analyzing the influence of GO flake size on biosensing efficacy. GO flakes of varying sizes, from 1 µm to 20 µm, were prepared under controlled conditions, followed by characterization through SEM and XPS to evaluate their size, surface area, and C/O ratio. The biosensing performance was systematically assessed by rGO-FET biosensors, examining the effects of GO flake size, C/O ratio, and film thickness. PACAP38 was employed as a biomarker for receptor-mediated detection, while chlorine ions served as model analytes for receptor-free small molecule detection. The results indicate that decreasing the GO flake size enhanced the performance for both target biomolecules. These findings highlight the crucial importance of selecting GO flake sizes specific to target analytes and detection strategies, thereby optimizing biosensor efficiency.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-02-05
DOI
https://doi.org/10.3390/bios15020086
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of GO Flake Size on Field-Effect Transistor (FET)-Based Biosensor Performance for Detection of Ions and PACAP 38

Jinsik Kim, Jae‐Joon Lee, Jaeyoon Song, Jongdeok Park et al.
2 citations
Biosensors
Analytical Chemistry and Sensors
1.47
article

The Effect of GO Flake Size on Field-Effect Transistor (FET)-Based Biosensor Performance for Detection of Ions and PACAP 38

Jinsik Kim, Jae‐Joon Lee, Jaeyoon Song, Jongdeok Park, Seung Jun Lee
article en
2 citations

Abstract

The performance development of rGO-FET biosensors by analyzing the influence of GO flake size on biosensing efficacy. GO flakes of varying sizes, from 1 µm to 20 µm, were prepared under controlled conditions, followed by characterization through SEM and XPS to evaluate their size, surface area, and C/O ratio. The biosensing performance was systematically assessed by rGO-FET biosensors, examining the effects of GO flake size, C/O ratio, and film thickness. PACAP38 was employed as a biomarker for receptor-mediated detection, while chlorine ions served as model analytes for receptor-free small molecule detection. The results indicate that decreasing the GO flake size enhanced the performance for both target biomolecules. These findings highlight the crucial importance of selecting GO flake sizes specific to target analytes and detection strategies, thereby optimizing biosensor efficiency.

BiosensorsVol. 15(2)
Dongguk University (KR)
National Research Foundation, Ministry of Trade, Industry and Energy, Korea Institute for Advancement of Technology, National Research Foundation of Korea, Korea Evaluation Institute of Industrial Technology
Affordable and clean energy
Openalex Percentile: Top 23%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.