Bi-directional reflectance and Raman characterizations of Spectralons with varying albedos

We measured the spectral bi-directional reflectance distribution function (BRDF) of 8 Spectralon calibration plaques with nominal reflectance values of 2%, 5%, 10%, 20%, 40%, 60%, 80%, and 99%, across a wavelength range of 350 to 2150 nm. The measurements were taken at two incident zenith angles, 0° and 60°. At normal incidence, the BRDF of the 40% Spectralon exhibits the most Lambertian behavior, while all other Spectralons exhibit both backscattering and forward-scattering lobes. However, at 60° incidence, the 99% Spectralon shows the best Lambertian behavior. Additionally, several particulate samples with varying albedos were calibrated using these Spectralon standards. The results indicate that while the angular shapes of the BRDF are not influenced by the specific plaque used, the absolute REFF values calibrated by the 99% plaque are consistently the highest.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-05
DOI
https://doi.org/10.1364/oe.543840
Citations
1
Primary Topic
Astro and Planetary Science
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bi-directional reflectance and Raman characterizations of Spectralons with varying albedos

Yuriy Shkuratov, Hao Zhang, D. T. Britt, Han Zheng
1 citations
Optics Express
Astro and Planetary Science
1.15
article

Bi-directional reflectance and Raman characterizations of Spectralons with varying albedos

Yuriy Shkuratov, Hao Zhang, D. T. Britt, Han Zheng
article en
1 citations

Abstract

We measured the spectral bi-directional reflectance distribution function (BRDF) of 8 Spectralon calibration plaques with nominal reflectance values of 2%, 5%, 10%, 20%, 40%, 60%, 80%, and 99%, across a wavelength range of 350 to 2150 nm. The measurements were taken at two incident zenith angles, 0° and 60°. At normal incidence, the BRDF of the 40% Spectralon exhibits the most Lambertian behavior, while all other Spectralons exhibit both backscattering and forward-scattering lobes. However, at 60° incidence, the 99% Spectralon shows the best Lambertian behavior. Additionally, several particulate samples with varying albedos were calibrated using these Spectralon standards. The results indicate that while the angular shapes of the BRDF are not influenced by the specific plaque used, the absolute REFF values calibrated by the 99% plaque are consistently the highest.

Optics ExpressVol. 33(4)
University of Central Florida (US), China University of Geosciences (CN), Center for Excellence in Education (US), V. N. Karazin Kharkiv National University (UA)
National Natural Science Foundation of China, Central Universities in China
Climate action
Openalex Percentile: Top 21%
Astro and Planetary Science
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bi-directional reflectance and Raman characterizations of Spectralons with varying albedos — Yuriy Shkuratov, Hao Zhang, et al. · Optics Express (2025) | TGRS Research Map | TGRS