Conversion technique of pulsatile-to-continuous flow single vascular assist device

Patients with a congenital heart disease and unfavourable anatomy that are not amenable to the primary correction of the defect might need a ventricular assist device as a bridge to a transplant. Pulsatile paracorporeal ventricular assist devices represent excellent options for supporting these patients with complex conditions. The Berlin Heart EXCOR is a such a paracorporeal pulsatile ventricular device. Pulsatile flow is more physiologic because it resembles the natural circulation pumped by the heart. The Berlin Heart EXCOR is a displacement pump; therefore, the risk for increased haemolysis is greater. If the patient experiences haemolysis despite a change the pump flow rate while on a Berlin Heart EXCOR ventricular assist device, a pump exchange to continuous flow may be beneficial. In this case report, we present a patient with severe haemolysis due to a displacement pump and the step-by-step technique for changing from a pulsatile to a continuous flow ventricular assist device.

Authors

Institutions

Publication Details

Journal
Multimedia Manual of Cardio-Thoracic Surgery
Published
2025-02-05
DOI
https://doi.org/10.1510/mmcts.2024.125
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conversion technique of pulsatile-to-continuous flow single vascular assist device

Yuriy Stukov, Giles J. Peek, Jeffrey Phillip Jacobs, Mark S. Bleiweis et al.
Multimedia Manual of Cardio-Thoracic Surgery
Mechanical Circulatory Support Devices
article

Conversion technique of pulsatile-to-continuous flow single vascular assist device

Yuriy Stukov, Giles J. Peek, Jeffrey Phillip Jacobs, Mark S. Bleiweis, Kayla V Lucas
article en

Abstract

Patients with a congenital heart disease and unfavourable anatomy that are not amenable to the primary correction of the defect might need a ventricular assist device as a bridge to a transplant. Pulsatile paracorporeal ventricular assist devices represent excellent options for supporting these patients with complex conditions. The Berlin Heart EXCOR is a such a paracorporeal pulsatile ventricular device. Pulsatile flow is more physiologic because it resembles the natural circulation pumped by the heart. The Berlin Heart EXCOR is a displacement pump; therefore, the risk for increased haemolysis is greater. If the patient experiences haemolysis despite a change the pump flow rate while on a Berlin Heart EXCOR ventricular assist device, a pump exchange to continuous flow may be beneficial. In this case report, we present a patient with severe haemolysis due to a displacement pump and the step-by-step technique for changing from a pulsatile to a continuous flow ventricular assist device.

Multimedia Manual of Cardio-Thoracic SurgeryVol. 2025
University of Florida (US)
Good health and well-being
Openalex Percentile: Top 98%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Conversion technique of pulsatile-to-continuous flow single vascular assist device — Yuriy Stukov, Giles J. Peek, et al. · Multimedia Manual of Cardio-Thoracic Surgery (2025) | TGRS Research Map | TGRS