Mechanism of Fatigue Crack Closure in Steel Under High‐Density Pulsed Current

ABSTRACT This study is aimed at clarifying the mechanism of effectively healing fatigue cracks in steel; austenitic stainless steel, SUS304; and hot work tool steel, SKD61, using high‐density pulsed current. The results show that the current concentration occurred at the crack tip for SUS304, and crack closure was observed near the fatigue crack tip. On the other hand, crack closure was observed at the notch tip in SKD61. The fatigue crack closure phenomena were verified by finite element analysis, revealing that contact pressure was applied behind the crack tip owing to local bending deformation associated with residual stress near the crack tip. For effective crack healing, it is necessary to bond the interface leveraging compressive stress and Joule heat generated at the crack tip during current application.

Authors

Institutions

Publication Details

Journal
Fatigue & Fracture of Engineering Materials & Structures
Published
2025-02-03
DOI
https://doi.org/10.1111/ffe.14579
Citations
6
Primary Topic
Electromagnetic Effects on Materials
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanism of Fatigue Crack Closure in Steel Under High‐Density Pulsed Current

Yuichi Furukawa, Atsushi HOSOI, Hiroyuki KAWADA, Takashi Tomita et al.
6 citations
Fatigue & Fracture of Engineering Materials & Structures
Electromagnetic Effects on Materials
4.38
article

Mechanism of Fatigue Crack Closure in Steel Under High‐Density Pulsed Current

Yuichi Furukawa, Atsushi HOSOI, Hiroyuki KAWADA, Takashi Tomita, Shota Nakayama, Yutaro Sugeno, Tomoto Kambayashi
article en
6 citations

Abstract

ABSTRACT This study is aimed at clarifying the mechanism of effectively healing fatigue cracks in steel; austenitic stainless steel, SUS304; and hot work tool steel, SKD61, using high‐density pulsed current. The results show that the current concentration occurred at the crack tip for SUS304, and crack closure was observed near the fatigue crack tip. On the other hand, crack closure was observed at the notch tip in SKD61. The fatigue crack closure phenomena were verified by finite element analysis, revealing that contact pressure was applied behind the crack tip owing to local bending deformation associated with residual stress near the crack tip. For effective crack healing, it is necessary to bond the interface leveraging compressive stress and Joule heat generated at the crack tip during current application.

Fatigue & Fracture of Engineering Materials & StructuresVol. 48(4)
Waseda University (JP), Toyota Motor Corporation (Japan) (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 6%
Electromagnetic Effects on Materials
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mechanism of Fatigue Crack Closure in Steel Under High‐Density Pulsed Current — Yuichi Furukawa, Atsushi HOSOI, et al. · Fatigue & Fracture of Engineering Materials & Structures (2025) | TGRS Research Map | TGRS