Perspective: Use of protein S100B as a quality assurance marker for endovascular therapy in acute ischemic stroke

Mechanical thrombectomy (MT) is a highly effective treatment for ischemic stroke associated with large vessel occlusion. Given its complexity, this procedure is widely used throughout the world in hospitals with different levels of experience. Therefore, practical quality assurance is advised to ensure a high standard of care across the board. In this perspective article, we propose the implementation of measuring serum S100B after MT as a surrogate outcome parameter for the extent of tissue damage as an additional quality indicator for internal and external benchmarking in endovascular therapy. We focus on the analysis of patients, in whom there is a discrepancy between the expected (e.g., based on favorable preconditions) and the actual biomarker outcome. We aim to illustrate the advantages and drawbacks of measuring S100B after MT, reliably depicting the procedure's quality and its use for comparison and identification of "outlier" patients in MT patient cohorts for further process and single-case analysis.

Authors

Institutions

Publication Details

Journal
Frontiers in Neurology
Published
2025-02-04
DOI
https://doi.org/10.3389/fneur.2025.1488018
Citations
1
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perspective: Use of protein S100B as a quality assurance marker for endovascular therapy in acute ischemic stroke

Franziska Lieschke, Christian Foerch
1 citations
Frontiers in Neurology
Acute Ischemic Stroke Management
1.35
article

Perspective: Use of protein S100B as a quality assurance marker for endovascular therapy in acute ischemic stroke

Franziska Lieschke, Christian Foerch
article en
1 citations

Abstract

Mechanical thrombectomy (MT) is a highly effective treatment for ischemic stroke associated with large vessel occlusion. Given its complexity, this procedure is widely used throughout the world in hospitals with different levels of experience. Therefore, practical quality assurance is advised to ensure a high standard of care across the board. In this perspective article, we propose the implementation of measuring serum S100B after MT as a surrogate outcome parameter for the extent of tissue damage as an additional quality indicator for internal and external benchmarking in endovascular therapy. We focus on the analysis of patients, in whom there is a discrepancy between the expected (e.g., based on favorable preconditions) and the actual biomarker outcome. We aim to illustrate the advantages and drawbacks of measuring S100B after MT, reliably depicting the procedure's quality and its use for comparison and identification of "outlier" patients in MT patient cohorts for further process and single-case analysis.

Frontiers in NeurologyVol. 16
Goethe University Frankfurt (DE), University Hospital Frankfurt (DE), Klinikum Ludwigsburg (DE)
Openalex Percentile: Top 23%
Acute Ischemic Stroke Management
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.