Direct digital synthesizer modeling at frequency images

An attempt to implement AD9912 DDS at first and second image frequency revealed a noticeable discrepancy of calculated phase noise with the measurement results, as particular the output phase noise at 1080 MHz was less then at 840 MHz with clock frequency 1 GHz. To mitigate this mismatch a new reconstruction pulse model was developed in assumption that D/A converter of DDS consists of two interleaved converters active for half a clock time. The results of calculations of frequency response both with phase and amplitude noise spectral density with proposed model are given. The experiment demonstrates a good match with model for phase and amplitude noise up to fifth frequency image. Measurements made with DDS AD9910 show similar results. At the same time, AD9914 has a normal frequency response, and its phase noise changes as f 2 up to 3,5 GHz with clock frequency 1 GHz.

Authors

Publication Details

Journal
Radioengineering
Published
2024-12-12
DOI
https://doi.org/10.18127/j00338486-202412-09
Primary Topic
Numerical Methods and Algorithms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct digital synthesizer modeling at frequency images

A.V. Korolev, S.G. Rykov
Radioengineering
Numerical Methods and Algorithms
article

Direct digital synthesizer modeling at frequency images

A.V. Korolev, S.G. Rykov
article en

Abstract

An attempt to implement AD9912 DDS at first and second image frequency revealed a noticeable discrepancy of calculated phase noise with the measurement results, as particular the output phase noise at 1080 MHz was less then at 840 MHz with clock frequency 1 GHz. To mitigate this mismatch a new reconstruction pulse model was developed in assumption that D/A converter of DDS consists of two interleaved converters active for half a clock time. The results of calculations of frequency response both with phase and amplitude noise spectral density with proposed model are given. The experiment demonstrates a good match with model for phase and amplitude noise up to fifth frequency image. Measurements made with DDS AD9910 show similar results. At the same time, AD9914 has a normal frequency response, and its phase noise changes as f 2 up to 3,5 GHz with clock frequency 1 GHz.

Radioengineering
Openalex Percentile: Top 69%
Numerical Methods and Algorithms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.