Microscopic and Biomechanical Analysis of PEEK Interspinous Spacers for Spinal Fusion Applications

Spinal fusion is a surgical intervention used to join two or more vertebrae in the spine. An often-used method involves the placement of intervertebral spacers. They are commonly composed of biocompatible materials like polyetheretherketone. It has strength, longevity, and the capacity to interact harmoniously with the human body. Standardized mechanical tests were performed on two distinct implants to assess their biomechanical characteristics. The studies were conducted at a velocity of 2 mm/min. The stopping criteria were determined based on the loads sustained by the 50th percentile. Furthermore, the chemical composition of the implants was assessed using Raman spectroscopy. The implant created via subtractive manufacturing has a significant change in its elastic region at a force of 1300 N, and it begins subsidence when vertebrae are subjected to a load of 1500 N. The integration of microscopic characterization techniques with the mechanical analysis of prostheses in numerous case studies facilitates the biomechanical evaluation of implants.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-02-04
DOI
https://doi.org/10.3390/ma18030679
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microscopic and Biomechanical Analysis of PEEK Interspinous Spacers for Spinal Fusion Applications

José Alejandro Hernández-Benítez, Christopher René Torres‐SanMiguel, Aída Verónica Rodríguez-Tovar, Elliot Alonso Alcántara-Arreola
1 links
Materials
Orthopaedic implants and arthroplasty
article

Microscopic and Biomechanical Analysis of PEEK Interspinous Spacers for Spinal Fusion Applications

José Alejandro Hernández-Benítez, Christopher René Torres‐SanMiguel, Aída Verónica Rodríguez-Tovar, Elliot Alonso Alcántara-Arreola
article en

Abstract

Spinal fusion is a surgical intervention used to join two or more vertebrae in the spine. An often-used method involves the placement of intervertebral spacers. They are commonly composed of biocompatible materials like polyetheretherketone. It has strength, longevity, and the capacity to interact harmoniously with the human body. Standardized mechanical tests were performed on two distinct implants to assess their biomechanical characteristics. The studies were conducted at a velocity of 2 mm/min. The stopping criteria were determined based on the loads sustained by the 50th percentile. Furthermore, the chemical composition of the implants was assessed using Raman spectroscopy. The implant created via subtractive manufacturing has a significant change in its elastic region at a force of 1300 N, and it begins subsidence when vertebrae are subjected to a load of 1500 N. The integration of microscopic characterization techniques with the mechanical analysis of prostheses in numerous case studies facilitates the biomechanical evaluation of implants.

MaterialsVol. 18(3)
Instituto Politécnico Nacional (MX)
Instituto Politécnico Nacional
Openalex Percentile: Top 96%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microscopic and Biomechanical Analysis of PEEK Interspinous Spacers for Spinal Fusion Applications — José Alejandro Hernández-Benítez, Christopher René Torres‐SanMiguel, et al. · Materials (2025) | TGRS Research Map | TGRS