Measurement of Fusion Control with Eye Tracking Device in Intermittent Exotropia

<b>Background/Objectives</b>: We wished to develop an automated method for quantifying fusion control in patients with intermittent exotropia (IXT) using an eye tracking device. <b>Methods</b>: Fifty subjects fixated on visual targets on an LCD monitor at a distance of 45 cm, consisting of dots moving horizontally and vertically and randomly appearing dots at fixed positions. The control group consisted of participants with less than 5 prism diopters (PD), and the IXT group consisted of IXT patients with 10 PD or more, excluding divergence excess types. Fixation disparity (FD) was measured using an eye tracking device, and the FD score was compared with the Newcastle Control Score (NCS) and the Mayo Clinic office-based scale (OCS) score. The subjects repeated the test twice, and the test-retest reliability was determined. <b>Results</b>: The fixation disparity scores of the IXT group during horizontal pursuit, vertical pursuit, and random dot fixation showed positive correlations with the NCS (r = 0.549, 0.583, and 0.481, respectively) and OCS score (r = 0.551, 0.570, and 0.505, respectively). The test-retest reliability of the FD scores of the IXT group using an eye tracking device was fair to good for each task (ICC = 0.633, 0.656, and 0.697, respectively). <b>Conclusions</b>: The eye tracking device developed for automated measurement of fusion control has the potential to assist in functional assessments of IXT.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-02-04
DOI
https://doi.org/10.3390/diagnostics15030361
Citations
1
Primary Topic
Ophthalmology and Eye Disorders
Type
article
Field-Weighted Citation Impact
1.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Fusion Control with Eye Tracking Device in Intermittent Exotropia

Sang Beom Han, Hee Kyung Yang, Dong Hyun Kim, Jeong Min Hwang
1 citations
Diagnostics
Ophthalmology and Eye Disorders
1.47
article

Measurement of Fusion Control with Eye Tracking Device in Intermittent Exotropia

Sang Beom Han, Hee Kyung Yang, Dong Hyun Kim, Jeong Min Hwang
article en
1 citations

Abstract

<b>Background/Objectives</b>: We wished to develop an automated method for quantifying fusion control in patients with intermittent exotropia (IXT) using an eye tracking device. <b>Methods</b>: Fifty subjects fixated on visual targets on an LCD monitor at a distance of 45 cm, consisting of dots moving horizontally and vertically and randomly appearing dots at fixed positions. The control group consisted of participants with less than 5 prism diopters (PD), and the IXT group consisted of IXT patients with 10 PD or more, excluding divergence excess types. Fixation disparity (FD) was measured using an eye tracking device, and the FD score was compared with the Newcastle Control Score (NCS) and the Mayo Clinic office-based scale (OCS) score. The subjects repeated the test twice, and the test-retest reliability was determined. <b>Results</b>: The fixation disparity scores of the IXT group during horizontal pursuit, vertical pursuit, and random dot fixation showed positive correlations with the NCS (r = 0.549, 0.583, and 0.481, respectively) and OCS score (r = 0.551, 0.570, and 0.505, respectively). The test-retest reliability of the FD scores of the IXT group using an eye tracking device was fair to good for each task (ICC = 0.633, 0.656, and 0.697, respectively). <b>Conclusions</b>: The eye tracking device developed for automated measurement of fusion control has the potential to assist in functional assessments of IXT.

DiagnosticsVol. 15(3)
Seoul National University Bundang Hospital (KR), Nune Eye Hospital (KR)
Seoul National University Bundang Hospital, National Research Foundation of Korea
Openalex Percentile: Top 23%
Ophthalmology and Eye Disorders
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.