Using the Tissue Impulse Response Function to Streamline Fractionated MRgFUS-Induced Hyperthermia

<b>Background/Objectives</b>: Combining radiation therapy with mild hyperthermia, especially via magnetic resonance-guided focused ultrasound (MRgFUS), holds promise for enhancing tumor control and alleviating symptoms in cancer patients. However, current clinical applications of MRgFUS focus primarily on ablative treatments, and using MRI guidance for each radiation session increases treatment costs and logistical demands. This study aimed to test a streamlined workflow for repeated hyperthermia treatments that reduces the need for continuous MRI monitoring, using an approach based on impulse response function (Green's function) to optimize acoustic power settings in advance. <b>Methods</b>: We implemented the Green's function approach in a perfused, tissue-mimicking phantom, conducting 30 experiments to simulate hyperthermia delivery via MRgFUS. Pre-calculated acoustic power settings were applied to maintain a stable hyperthermia target without the need for real-time feedback control from MRI thermometry. Additionally, a retrospective analysis of patient thermometry data from MRgFUS sonications was performed to assess feasibility in clinical contexts. <b>Results</b>: Our experiments demonstrated consistent, stable hyperthermia (+7 °C) for 15 min across varying perfusion rates, outperforming conventional closed-loop MRI feedback methods in maintaining temperature stability. The retrospective analysis confirmed that this method is noise-robust and clinically applicable. <b>Conclusions</b>: This off-line approach to hyperthermia control could simplify the integration of MRgFUS hyperthermia in cancer treatment, reducing costs and logistical barriers. These findings suggest that our method may enable the broader adoption of hyperthermia in radiation therapy, supporting its role as a viable adjuvant treatment in oncology.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2025-02-04
DOI
https://doi.org/10.3390/cancers17030515
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using the Tissue Impulse Response Function to Streamline Fractionated MRgFUS-Induced Hyperthermia

Rarès Salomir, Vanessa Fleury, Lindsey A. Crowe, Sana Boudabbous et al.
Cancers
Ultrasound and Hyperthermia Applications
article

Using the Tissue Impulse Response Function to Streamline Fractionated MRgFUS-Induced Hyperthermia

Rarès Salomir, Vanessa Fleury, Lindsey A. Crowe, Sana Boudabbous, G. Dipasquale, Thomas Zilli, Yacine M’Rad, Shahan Momjian, Orane Lorton, P Guillemin, Anna Borich
article en

Abstract

<b>Background/Objectives</b>: Combining radiation therapy with mild hyperthermia, especially via magnetic resonance-guided focused ultrasound (MRgFUS), holds promise for enhancing tumor control and alleviating symptoms in cancer patients. However, current clinical applications of MRgFUS focus primarily on ablative treatments, and using MRI guidance for each radiation session increases treatment costs and logistical demands. This study aimed to test a streamlined workflow for repeated hyperthermia treatments that reduces the need for continuous MRI monitoring, using an approach based on impulse response function (Green's function) to optimize acoustic power settings in advance. <b>Methods</b>: We implemented the Green's function approach in a perfused, tissue-mimicking phantom, conducting 30 experiments to simulate hyperthermia delivery via MRgFUS. Pre-calculated acoustic power settings were applied to maintain a stable hyperthermia target without the need for real-time feedback control from MRI thermometry. Additionally, a retrospective analysis of patient thermometry data from MRgFUS sonications was performed to assess feasibility in clinical contexts. <b>Results</b>: Our experiments demonstrated consistent, stable hyperthermia (+7 °C) for 15 min across varying perfusion rates, outperforming conventional closed-loop MRI feedback methods in maintaining temperature stability. The retrospective analysis confirmed that this method is noise-robust and clinically applicable. <b>Conclusions</b>: This off-line approach to hyperthermia control could simplify the integration of MRgFUS hyperthermia in cancer treatment, reducing costs and logistical barriers. These findings suggest that our method may enable the broader adoption of hyperthermia in radiation therapy, supporting its role as a viable adjuvant treatment in oncology.

CancersVol. 17(3)
University of Geneva (CH), Institute of Oncology Research (CH), University Hospital of Geneva (CH), Istituto Oncologico della Svizzera Italiana, Università della Svizzera italiana (CH)
Innosuisse - Schweizerische Agentur für Innovationsförderung
Good health and well-being
Openalex Percentile: Top 98%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.