A dosimetric evaluation using the Monte Carlo method considering geometric variations of the Iodine-125 seed for brachytherapy

The Institute for Energy and Nuclear Research – IPEN-CNEN/SP is uniquely positioned to develop a new source of Iodine-125 for brachytherapy treatment. Therefore, research into the dosimetric process and source design is widely studied. Task Group 43 – TG 43 cites methodologies for dosimetry of sources for brachytherapy, the most used method is Monte Carlo. However, the dosimetric protocol does not mention possible variations in the source geometry after its conception. The investigative focus of the work was to obtain measurements of the Iodine-125 seed during the production stages until completion, quantify them and simulate them using the Monte Carlo method with the MCNP – 4C code, the formalism was in water and a 101x101 matrix was used to calculate the dose point by point. Two variations were chosen: a) seed length; b) nucleus length, using a batch of 100 seeds for each case. 100 simulations were carried out for each variation and one simulation using the reference seed geometry. The following calculations were applied: relative difference to compare variations to the reference; average among the 100 seeds of each batch to calculate the standard deviation. In both cases there was no point that exceeded 4.48% relative difference, and for standard deviation the largest point was 1.6%, while the Type A uncertainty was 0.018% at the largest point.

Authors

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2025-02-03
DOI
https://doi.org/10.15392/2319-0612.2024.2543
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dosimetric evaluation using the Monte Carlo method considering geometric variations of the Iodine-125 seed for brachytherapy

Carlos A. Zeituni, Lucas Verdi Angelocci, Carla Daruich de Souza, Maria Elisa Chuery Martins Rostelato et al.
Brazilian Journal of Radiation Sciences
Advanced Radiotherapy Techniques
article

A dosimetric evaluation using the Monte Carlo method considering geometric variations of the Iodine-125 seed for brachytherapy

Carlos A. Zeituni, Lucas Verdi Angelocci, Carla Daruich de Souza, Maria Elisa Chuery Martins Rostelato, Sabrina Spigaroli Sgrignoli, Henrique Santos de Chico
article en

Abstract

The Institute for Energy and Nuclear Research – IPEN-CNEN/SP is uniquely positioned to develop a new source of Iodine-125 for brachytherapy treatment. Therefore, research into the dosimetric process and source design is widely studied. Task Group 43 – TG 43 cites methodologies for dosimetry of sources for brachytherapy, the most used method is Monte Carlo. However, the dosimetric protocol does not mention possible variations in the source geometry after its conception. The investigative focus of the work was to obtain measurements of the Iodine-125 seed during the production stages until completion, quantify them and simulate them using the Monte Carlo method with the MCNP – 4C code, the formalism was in water and a 101x101 matrix was used to calculate the dose point by point. Two variations were chosen: a) seed length; b) nucleus length, using a batch of 100 seeds for each case. 100 simulations were carried out for each variation and one simulation using the reference seed geometry. The following calculations were applied: relative difference to compare variations to the reference; average among the 100 seeds of each batch to calculate the standard deviation. In both cases there was no point that exceeded 4.48% relative difference, and for standard deviation the largest point was 1.6%, while the Type A uncertainty was 0.018% at the largest point.

Brazilian Journal of Radiation SciencesVol. 12(4A (Suppl.))
Fundação de Amparo à Pesquisa do Estado de São Paulo, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Comissão Nacional de Energia Nuclear
Openalex Percentile: Top 98%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A dosimetric evaluation using the Monte Carlo method considering geometric variations of the Iodine-125 seed for brachytherapy — Carlos A. Zeituni, Lucas Verdi Angelocci, et al. · Brazilian Journal of Radiation Sciences (2025) | TGRS Research Map | TGRS