Engineered Receptor Capture Combined with Mass Spectrometry Enables High-Throughput Detection and Quantitation of SARS-CoV-2 Spike Protein

Mass spectrometry (MS) is a potentially powerful approach for the diagnostic detection of SARS-CoV-2 and other viruses. However, MS detection is compromised when viral antigens are present at low concentrations, especially in complex biological media. We hypothesized that viral receptors could be used for viral target capture to enable detection by MS under such conditions. This was tested using the extracellular domain of the SARS-CoV-2 receptor ACE2. To maximize recovery of the target protein, directed protein evolution was first used to increase the affinity of ACE2 for spike protein. This generated an evolved ACE2 with increased binding affinity for the spike protein receptor-binding domain (RBD). However, as with other affinity-enhanced evolved forms of ACE2, binding was sensitive to mutations in variant RBDs. As an alternative strategy to maximize capture, the native ACE2 extracellular domain was engineered for increased binding by the addition of an oligomerization scaffold to create pentameric ACE2. This bound extremely tightly to SARS-CoV-2 RBD, with an increase in apparent affinity of several thousand-fold over monomeric ACE2, and RBD retention of more than 8 h. Immobilization of multimeric ACE2 enabled quantitative enrichment of viral spike protein from saliva and increased the sensitivity of detection by MS. These data show that capture by engineered receptors combined with MS can be an effective, rapid method for detection and quantitation of target protein. A similar approach could be used for attachment proteins of other viruses or any target protein for which there are suitable receptors.

Authors

Institutions

Publication Details

Journal
JACS Au
Published
2025-02-04
DOI
https://doi.org/10.1021/jacsau.4c00980
Citations
1
Primary Topic
SARS-CoV-2 and COVID-19 Research
Type
article
Field-Weighted Citation Impact
1.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Engineered Receptor Capture Combined with Mass Spectrometry Enables High-Throughput Detection and Quantitation of SARS-CoV-2 Spike Protein

Dan Lane, Julian E. Sale, Farah Salim, Neil Bate et al.
1 citations
JACS Au
SARS-CoV-2 and COVID-19 Research
1.40
article

Engineered Receptor Capture Combined with Mass Spectrometry Enables High-Throughput Detection and Quantitation of SARS-CoV-2 Spike Protein

Dan Lane, Julian E. Sale, Farah Salim, Neil Bate, Natalie Allcock, Donald J. L. Jones, Richard Haigh, Nicholas P.J. Brindle, Siân E. Evans
article en
1 citations

Abstract

Mass spectrometry (MS) is a potentially powerful approach for the diagnostic detection of SARS-CoV-2 and other viruses. However, MS detection is compromised when viral antigens are present at low concentrations, especially in complex biological media. We hypothesized that viral receptors could be used for viral target capture to enable detection by MS under such conditions. This was tested using the extracellular domain of the SARS-CoV-2 receptor ACE2. To maximize recovery of the target protein, directed protein evolution was first used to increase the affinity of ACE2 for spike protein. This generated an evolved ACE2 with increased binding affinity for the spike protein receptor-binding domain (RBD). However, as with other affinity-enhanced evolved forms of ACE2, binding was sensitive to mutations in variant RBDs. As an alternative strategy to maximize capture, the native ACE2 extracellular domain was engineered for increased binding by the addition of an oligomerization scaffold to create pentameric ACE2. This bound extremely tightly to SARS-CoV-2 RBD, with an increase in apparent affinity of several thousand-fold over monomeric ACE2, and RBD retention of more than 8 h. Immobilization of multimeric ACE2 enabled quantitative enrichment of viral spike protein from saliva and increased the sensitivity of detection by MS. These data show that capture by engineered receptors combined with MS can be an effective, rapid method for detection and quantitation of target protein. A similar approach could be used for attachment proteins of other viruses or any target protein for which there are suitable receptors.

JACS AuVol. 5(2)
University of Leicester (GB), MRC Laboratory of Molecular Biology (GB)
National Institute for Health and Care Research, John and Lucille Van Geest Foundation, Directorate for Biological Sciences, Medical Research Council, Biotechnology and Biological Sciences Research Council, NIHR Leicester Biomedical Research Centre
Openalex Percentile: Top 24%
SARS-CoV-2 and COVID-19 Research
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.