Iron Oxide Scale Formation Mechanism and Anti-Corrosion Technology from Induction Remelting of Boiler Coating in Waste Incineration Power Plant

High-frequency induction welding technology represents the development direction of the high-temperature corrosion protection technology for the heating surfaces of the boiler "four tubes". However, when the high-frequency induction coil heats and remelts the coating on the tube's outer wall, the tube's inner wall is also heated, causing an iron oxide scale to form on the tube's inner wall. When the remelting temperature rises and the temperature of the tube's inner wall exceeds 580 °C, three layers of oxide films, FeO, Fe<sub>3</sub>O<sub>4</sub>, and Fe<sub>2</sub>O<sub>3</sub> are arranged in sequence from the substrate surface of the tube's inner wall to the outside, with a thickness ratio of approximately 1:10:100. From the XRD spectra of tube iron oxide scale, it can be seen that the oxidation of the tube. The skin is mainly composed of Fe<sub>3</sub>O<sub>4</sub>, with a certain amount of Fe<sub>2</sub>O<sub>3</sub> and trace amounts of FeO. The iron in the diffraction peak originates from the metal matrix. However, when the remelting temperature continues to rise and the temperature of the tube's inner wall exceeds 580 °C, the oxide film begins to thicken significantly, that is, the oxide film begins to transform into an oxide scale. Under the continuous action of high-temperature induction remelting, the reaction between iron and oxygen is accelerated, but because the oxygen ions of water slowly diffuse through two outer layers of oxide films, with a low oxygen concentration. Although the FeO film is thin, it has a loose structure and numerous lattice defects, is unstable and easy to decompose, and easily peels off from the tube's inner wall. For a pipe wall thickness of 5 mm, if the thinning rate of the inner wall caused by detachment reaches 0.8 mm/year, it is highly likely to cause pipe burst accidents within 4-5 years. The influence of the iron oxide scale on the performance of the tube's inner wall was evaluated by testing indexes, such as surface hardness and decarburization layer depth. Although the oxide scale reduces the surface hardness of the tube's inner wall, the surface decarburization layer is very thin, so the effect on the mechanical properties of the tube's substrate is limited. The technology of inhibiting the formation of the iron oxide scale in induction remelting is briefly introduced. During the high-frequency remelting process of water-cooled walls, as the tube bank moves forward relative to the high-frequency heating coil, nitrogen protection is used to suppress the formation of oxide scale, effectively eliminating the troubles caused by high-frequency induction remelting and achieving the goal of improving the service life of the tube bank. This technology of the nitrogen protection method is used to inhibit the formation of iron oxide scale, not only inhibiting the formation of the iron oxide scale on the tube inner wall and the back of the tube bundle, with remarkable experimental results and broad application prospects.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-02-04
DOI
https://doi.org/10.3390/molecules30030689
Citations
1
Primary Topic
Welding Techniques and Residual Stresses
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Iron Oxide Scale Formation Mechanism and Anti-Corrosion Technology from Induction Remelting of Boiler Coating in Waste Incineration Power Plant

Xinli Tian, Zuopeng Qu
1 citations
Molecules
Welding Techniques and Residual Stresses
0.71
article

Iron Oxide Scale Formation Mechanism and Anti-Corrosion Technology from Induction Remelting of Boiler Coating in Waste Incineration Power Plant

Xinli Tian, Zuopeng Qu
article en
1 citations

Abstract

High-frequency induction welding technology represents the development direction of the high-temperature corrosion protection technology for the heating surfaces of the boiler "four tubes". However, when the high-frequency induction coil heats and remelts the coating on the tube's outer wall, the tube's inner wall is also heated, causing an iron oxide scale to form on the tube's inner wall. When the remelting temperature rises and the temperature of the tube's inner wall exceeds 580 °C, three layers of oxide films, FeO, Fe<sub>3</sub>O<sub>4</sub>, and Fe<sub>2</sub>O<sub>3</sub> are arranged in sequence from the substrate surface of the tube's inner wall to the outside, with a thickness ratio of approximately 1:10:100. From the XRD spectra of tube iron oxide scale, it can be seen that the oxidation of the tube. The skin is mainly composed of Fe<sub>3</sub>O<sub>4</sub>, with a certain amount of Fe<sub>2</sub>O<sub>3</sub> and trace amounts of FeO. The iron in the diffraction peak originates from the metal matrix. However, when the remelting temperature continues to rise and the temperature of the tube's inner wall exceeds 580 °C, the oxide film begins to thicken significantly, that is, the oxide film begins to transform into an oxide scale. Under the continuous action of high-temperature induction remelting, the reaction between iron and oxygen is accelerated, but because the oxygen ions of water slowly diffuse through two outer layers of oxide films, with a low oxygen concentration. Although the FeO film is thin, it has a loose structure and numerous lattice defects, is unstable and easy to decompose, and easily peels off from the tube's inner wall. For a pipe wall thickness of 5 mm, if the thinning rate of the inner wall caused by detachment reaches 0.8 mm/year, it is highly likely to cause pipe burst accidents within 4-5 years. The influence of the iron oxide scale on the performance of the tube's inner wall was evaluated by testing indexes, such as surface hardness and decarburization layer depth. Although the oxide scale reduces the surface hardness of the tube's inner wall, the surface decarburization layer is very thin, so the effect on the mechanical properties of the tube's substrate is limited. The technology of inhibiting the formation of the iron oxide scale in induction remelting is briefly introduced. During the high-frequency remelting process of water-cooled walls, as the tube bank moves forward relative to the high-frequency heating coil, nitrogen protection is used to suppress the formation of oxide scale, effectively eliminating the troubles caused by high-frequency induction remelting and achieving the goal of improving the service life of the tube bank. This technology of the nitrogen protection method is used to inhibit the formation of iron oxide scale, not only inhibiting the formation of the iron oxide scale on the tube inner wall and the back of the tube bundle, with remarkable experimental results and broad application prospects.

MoleculesVol. 30(3)
North China Electric Power University (CN)
Openalex Percentile: Top 36%
Welding Techniques and Residual Stresses
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.