PREVENTION OF THE DEVELOPMENT OF FAILURE OF COLON ANASTOMOSES

Abstract. Objective. Development of a method to prevent the development of failure of large intestinal anastomoses. Research materials and methods. The results of treatment of 127 patients were studied. Colonic anastomosis was performed in 78 patients using a disposable double-row circular stapling device. To 49 patients was used, a disposable three-row circular anastomosis and a local hemostatic agent. Results and discussion. We have improved the method of restoring of the colon. The supporting head of the circular stapling device is placed in the proximal part of the large intestine. A pocket suture is applied and tightened. The distal end of the intestine is sutured. The suturing device is passed through the anus, the distal stump of the rectum is pierced. The Tahocomb plate is fixed on the thrust head. The ends of the intestine are sew with a three-row staple suture. The line of anastomosis is covered with a second Tahocomb plate. Conclusions. Suture line failure was 2.04% versus 3.84% of cases in the comparison group. The method is based on the synergism of the hemostatic and sealing effect of Тahokomb and the provision of mechanical tightness with the help of a three-row seam.

Authors

Publication Details

Journal
Kharkiv Surgical School
Published
2024-11-20
DOI
https://doi.org/10.37699/2308-7005.5.2024.03
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PREVENTION OF THE DEVELOPMENT OF FAILURE OF COLON ANASTOMOSES

D. V. Okley, S. О. Nemenko, D. О. Yevtushenko
Kharkiv Surgical School
Colorectal Cancer Surgical Treatments
article

PREVENTION OF THE DEVELOPMENT OF FAILURE OF COLON ANASTOMOSES

D. V. Okley, S. О. Nemenko, D. О. Yevtushenko
article en

Abstract

Abstract. Objective. Development of a method to prevent the development of failure of large intestinal anastomoses. Research materials and methods. The results of treatment of 127 patients were studied. Colonic anastomosis was performed in 78 patients using a disposable double-row circular stapling device. To 49 patients was used, a disposable three-row circular anastomosis and a local hemostatic agent. Results and discussion. We have improved the method of restoring of the colon. The supporting head of the circular stapling device is placed in the proximal part of the large intestine. A pocket suture is applied and tightened. The distal end of the intestine is sutured. The suturing device is passed through the anus, the distal stump of the rectum is pierced. The Tahocomb plate is fixed on the thrust head. The ends of the intestine are sew with a three-row staple suture. The line of anastomosis is covered with a second Tahocomb plate. Conclusions. Suture line failure was 2.04% versus 3.84% of cases in the comparison group. The method is based on the synergism of the hemostatic and sealing effect of Тahokomb and the provision of mechanical tightness with the help of a three-row seam.

Kharkiv Surgical School(5)
Openalex Percentile: Top 58%
Colorectal Cancer Surgical Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.