How does Independent Component Analysis Preprocessing Affect EEG Microstates?

Over recent years, electroencephalographic (EEG) microstates have been increasingly used to investigate, at a millisecond scale, the temporal dynamics of large-scale brain networks. By studying their topography and chronological sequence, microstates research has contributed to the understanding of the brain's functional organization at rest and its alteration in neurological or mental disorders. Artifact removal strategies, which differ from study to study, may alter microstates topographies and features, possibly reducing the generalizability and comparability of results across research groups. The aim of this work was therefore to test the reliability of the microstate extraction process and the stability of microstate features against different strategies of EEG data preprocessing with Independent Component Analysis (ICA) to remove artifacts embedded in the data. A normative resting state EEG dataset was used where subjects alternate eyes-open (EO) and eyes-closed (EC) periods. Four strategies were tested: (i) avoiding ICA preprocessing altogether, (ii) removing ocular artifacts only, (iii) removing all reliably identified physiological/non physiological artifacts, (iv) retaining only reliably identified brain ICs. Results show that skipping the removal of ocular artifacts affects the stability of microstate evaluation criteria, microstate topographies and greatly reduces the statistical power of EO/EC microstate features comparisons, however differences are not as prominent with more aggressive preprocessing. Provided a good-quality dataset is recorded, and ocular artifacts are removed, microstates topographies and features can capture brain-related physiological data and are robust to artifacts, independently of the level of preprocessing, paving the way to automatized microstate extraction pipelines.

Authors

Institutions

Publication Details

Journal
Brain Topography
Published
2025-02-04
DOI
https://doi.org/10.1007/s10548-024-01098-4
Citations
9
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
12.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

How does Independent Component Analysis Preprocessing Affect EEG Microstates?

Christoph M. Michel, Fiorenzo Artoni
9 citations
Brain Topography
EEG and Brain-Computer Interfaces
12.88
article

How does Independent Component Analysis Preprocessing Affect EEG Microstates?

Christoph M. Michel, Fiorenzo Artoni
article en
9 citations

Abstract

Over recent years, electroencephalographic (EEG) microstates have been increasingly used to investigate, at a millisecond scale, the temporal dynamics of large-scale brain networks. By studying their topography and chronological sequence, microstates research has contributed to the understanding of the brain's functional organization at rest and its alteration in neurological or mental disorders. Artifact removal strategies, which differ from study to study, may alter microstates topographies and features, possibly reducing the generalizability and comparability of results across research groups. The aim of this work was therefore to test the reliability of the microstate extraction process and the stability of microstate features against different strategies of EEG data preprocessing with Independent Component Analysis (ICA) to remove artifacts embedded in the data. A normative resting state EEG dataset was used where subjects alternate eyes-open (EO) and eyes-closed (EC) periods. Four strategies were tested: (i) avoiding ICA preprocessing altogether, (ii) removing ocular artifacts only, (iii) removing all reliably identified physiological/non physiological artifacts, (iv) retaining only reliably identified brain ICs. Results show that skipping the removal of ocular artifacts affects the stability of microstate evaluation criteria, microstate topographies and greatly reduces the statistical power of EO/EC microstate features comparisons, however differences are not as prominent with more aggressive preprocessing. Provided a good-quality dataset is recorded, and ocular artifacts are removed, microstates topographies and features can capture brain-related physiological data and are robust to artifacts, independently of the level of preprocessing, paving the way to automatized microstate extraction pipelines.

Brain TopographyVol. 38(2)
University of Geneva (CH), Centre d'Imagerie BioMedicale (CH), Politecnico di Milano (IT)
Université de Genève
Openalex Percentile: Top 1%
EEG and Brain-Computer Interfaces
12.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.