Assessing radiological properties of novel tissue equivalent materials for heterogeneous pediatric head phantom: Experimental insights and Monte Carlo simulations

This study addresses the need for realistic substitute materials in pediatric head CT to enhance imaging safety. Epoxy resin-based composites were developed to mimic cranial bone, brain tissue, cerebrospinal fluid and eye lens. Radiological properties were validated using Monte Carlo simulations and XMuDat software, with CT numbers measured on a 64-detector CT scanner at 80, 100, and 120 kVp. A comparison was applied against standard tissues from the International Commission on Radiation Units and Measurements (ICRU). For cranial bone, a composite of 70 % epoxy resin and 30 % calcium carbonate achieved a density of 1.65 g/cm³ and Z eff = 11.02, with deviations in mass attenuation coefficients from ICRU standard ranging from 17.4 % at 40 keV to 1.2 % at 150 keV. Brain matter (95 % resin, 5 % acetone) achieved Z eff = 6.19, with deviations from the ICRU standard ranging from 13.7 % to 5.5 %. CSF (80 % resin, 15 % silica, 5 % acetone) closely matched water, with deviations from the water standard ranging from 3.4 % to 1.1 %. Eye lens (95 % resin, 5 % sodium bicarbonate) achieved Z eff = 6.47, with deviations from ICRU standard ranging from 7.5 % to 4.2 %. These results demonstrate the potential of epoxy resin-based substitutes to approximate ICRU standard tissues supporting safer pediatric radiology protocols customized to this sensitive population.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-02-04
DOI
https://doi.org/10.1016/j.net.2025.103525
Citations
6
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
11.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing radiological properties of novel tissue equivalent materials for heterogeneous pediatric head phantom: Experimental insights and Monte Carlo simulations

H. Sekkat, A. Khallouqi, Youssef Madkouri, Omar El Rhazouani et al.
6 citations
Nuclear Engineering and Technology
Advanced Radiotherapy Techniques
11.30
article

Assessing radiological properties of novel tissue equivalent materials for heterogeneous pediatric head phantom: Experimental insights and Monte Carlo simulations

H. Sekkat, A. Khallouqi, Youssef Madkouri, Omar El Rhazouani, Abdellah Halimi
article en
6 citations

Abstract

This study addresses the need for realistic substitute materials in pediatric head CT to enhance imaging safety. Epoxy resin-based composites were developed to mimic cranial bone, brain tissue, cerebrospinal fluid and eye lens. Radiological properties were validated using Monte Carlo simulations and XMuDat software, with CT numbers measured on a 64-detector CT scanner at 80, 100, and 120 kVp. A comparison was applied against standard tissues from the International Commission on Radiation Units and Measurements (ICRU). For cranial bone, a composite of 70 % epoxy resin and 30 % calcium carbonate achieved a density of 1.65 g/cm³ and Z eff = 11.02, with deviations in mass attenuation coefficients from ICRU standard ranging from 17.4 % at 40 keV to 1.2 % at 150 keV. Brain matter (95 % resin, 5 % acetone) achieved Z eff = 6.19, with deviations from the ICRU standard ranging from 13.7 % to 5.5 %. CSF (80 % resin, 15 % silica, 5 % acetone) closely matched water, with deviations from the water standard ranging from 3.4 % to 1.1 %. Eye lens (95 % resin, 5 % sodium bicarbonate) achieved Z eff = 6.47, with deviations from ICRU standard ranging from 7.5 % to 4.2 %. These results demonstrate the potential of epoxy resin-based substitutes to approximate ICRU standard tissues supporting safer pediatric radiology protocols customized to this sensitive population.

Nuclear Engineering and TechnologyVol. 57(7)
Université Ibn-Tofail (MA), Université Mohammed VI des Sciences et de la Santé (MA), Université Hassan 1er (MA), Hospital del Mar Research Institute (ES)
Université Hassan 1er
Openalex Percentile: Top 1%
Advanced Radiotherapy Techniques
11.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.