Product photography as a tool supporting Attribute Agreement Analysis

The goal of the work is to present the method concept of the attribute agreement analysis (evaluation of visual inspection) aided by product photography The results of a proof of concept study in laboratory conditions are presented. The research was performed based on the control process of medical product - a disposable transducer for determining hemodynamic blood parameters. As part of the proof of concept study, a test with three raters and one expert was conducted. For verification purposes, two types of visual control study results were compared, i.e. the level of agreement of assessment decisions made on physical objects and on their digital representatives. A measurement and control system analysis for attributes (MSA-AAA) study were carried out using the Cross-Tab method with Kappa-Cohen’s coefficient and Gwet’s AC1 coefficient. Comparing the results obtained from the study, the final conclusion is that the method using product photography as a supporting tool in AAA is effective. The verification was performed at the Poznan University of Technology, Poland, in the Data Analysis Laboratory with laboratory workstation Orbitvu Alphashot Micro.

Authors

Institutions

Publication Details

Published
2024-12-15
DOI
https://doi.org/10.1109/ieem62345.2024.10857240
Primary Topic
Semantic Web and Ontologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Product photography as a tool supporting Attribute Agreement Analysis

Wojciech Rudzki, Magdalena HRYB
Semantic Web and Ontologies
article

Product photography as a tool supporting Attribute Agreement Analysis

Wojciech Rudzki, Magdalena HRYB
article en

Abstract

The goal of the work is to present the method concept of the attribute agreement analysis (evaluation of visual inspection) aided by product photography The results of a proof of concept study in laboratory conditions are presented. The research was performed based on the control process of medical product - a disposable transducer for determining hemodynamic blood parameters. As part of the proof of concept study, a test with three raters and one expert was conducted. For verification purposes, two types of visual control study results were compared, i.e. the level of agreement of assessment decisions made on physical objects and on their digital representatives. A measurement and control system analysis for attributes (MSA-AAA) study were carried out using the Cross-Tab method with Kappa-Cohen’s coefficient and Gwet’s AC1 coefficient. Comparing the results obtained from the study, the final conclusion is that the method using product photography as a supporting tool in AAA is effective. The verification was performed at the Poznan University of Technology, Poland, in the Data Analysis Laboratory with laboratory workstation Orbitvu Alphashot Micro.

Poznań University of Technology (PL)
Openalex Percentile: Top 76%
Semantic Web and Ontologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Product photography as a tool supporting Attribute Agreement Analysis — Wojciech Rudzki, Magdalena HRYB · (2024) | TGRS Research Map | TGRS