Implications of Elevated Temperatures on the Accuracy of Pulsed-Laser SEE Testing

Elevated temperature can impact the accuracy of pulsed-laser (PL) single-event effect (SEE) testing primarily due to the temperature dependence of optical absorption. This is particularly true for laser wavelengths capable of through-wafer testing which are key for most recent-generation device technologies. This study accounts for the influence of temperature on the key parameter for PL testing, the laser-equivalent linear E<sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">nergy</small> transfer (LETL). This is accomplished by employing accurate models of the temperature-dependent absorption coefficients and validating the resulting calculations against experimental charge collection data over a range of wavelengths and temperatures. With this understanding, the impacts of elevated temperature on the accuracy of PL testing when investigating single-event transients (SETs) and single-event latchup (SEL) are discussed in terms of ramifications and approaches for remediation.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2025-02-04
DOI
https://doi.org/10.1109/tns.2025.3538531
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implications of Elevated Temperatures on the Accuracy of Pulsed-Laser SEE Testing

Gregory R. Allen, Dale McMorrow, Adrian Ildefonso, Ani Khachatrian et al.
IEEE Transactions on Nuclear Science
Non-Destructive Testing Techniques
article

Implications of Elevated Temperatures on the Accuracy of Pulsed-Laser SEE Testing

Gregory R. Allen, Dale McMorrow, Adrian Ildefonso, Ani Khachatrian, Joel M. Hales
article en

Abstract

Elevated temperature can impact the accuracy of pulsed-laser (PL) single-event effect (SEE) testing primarily due to the temperature dependence of optical absorption. This is particularly true for laser wavelengths capable of through-wafer testing which are key for most recent-generation device technologies. This study accounts for the influence of temperature on the key parameter for PL testing, the laser-equivalent linear E<sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">nergy</small> transfer (LETL). This is accomplished by employing accurate models of the temperature-dependent absorption coefficients and validating the resulting calculations against experimental charge collection data over a range of wavelengths and temperatures. With this understanding, the impacts of elevated temperature on the accuracy of PL testing when investigating single-event transients (SETs) and single-event latchup (SEL) are discussed in terms of ramifications and approaches for remediation.

IEEE Transactions on Nuclear ScienceVol. 72(4)
United States Naval Research Laboratory (US), Jet Propulsion Laboratory (US), Jacobs (United States) (US)
Openalex Percentile: Top 98%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Implications of Elevated Temperatures on the Accuracy of Pulsed-Laser SEE Testing — Gregory R. Allen, Dale McMorrow, et al. · IEEE Transactions on Nuclear Science (2025) | TGRS Research Map | TGRS