Monitoring Magnetic Flux Density of 100 KVA Transformer Operational Remotely

Transformers are important equipment in transmission and distribution networks. Its operation and control are important aspects which determine the reliability and quality of power supply. As many stepdown transformers are spread over a wide area in the present power system, it is difficult to monitor the condition of each transformer manually. Therefore, development of a Condition Monitoring System (CMS) for transformers is performed. This condition monitoring system can monitor several parameter values of a transformer in real time. This paper presents the design of a sensing system allowing measurement of magnetic flux and load parameter at the transformer. These parameters are current, voltage, temperature, magnetic flux density and total losses at any instant at a particular transformer. The sensors monitoring these parameters can be interfaced to master and slave microcontrollers working as an onboard computer at the transformer that can collect sensing data and send it to a hub monitoring the status of the transformers in power supply network to have continuous supply of power to consumers. The hub monitoring the transformer may be placed at the power distribution company and at the transformer manufacturer’s site to assess the performance of transformers statistically and take corrective action where it is necessary. The CMS is intended to be easily incorporated into the transformer configurations, requiring little modification of the existing infrastructure and easily manageable through recalibration and replacement of sensors every now and then. The system does, however, require initial installation costs, but these are offset by many advantages that include increased transformer lifespan, less operational time lost, and improved energy efficiency, with payback expected within 2-3 years.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1109/icit63607.2024.10860241
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Magnetic Flux Density of 100 KVA Transformer Operational Remotely

Arsalan Arif, Ajmal Bangash, Wasim Ahmed Khan, B. Fazle Wadood
Magnetic Field Sensors Techniques
article

Monitoring Magnetic Flux Density of 100 KVA Transformer Operational Remotely

Arsalan Arif, Ajmal Bangash, Wasim Ahmed Khan, B. Fazle Wadood
article en

Abstract

Transformers are important equipment in transmission and distribution networks. Its operation and control are important aspects which determine the reliability and quality of power supply. As many stepdown transformers are spread over a wide area in the present power system, it is difficult to monitor the condition of each transformer manually. Therefore, development of a Condition Monitoring System (CMS) for transformers is performed. This condition monitoring system can monitor several parameter values of a transformer in real time. This paper presents the design of a sensing system allowing measurement of magnetic flux and load parameter at the transformer. These parameters are current, voltage, temperature, magnetic flux density and total losses at any instant at a particular transformer. The sensors monitoring these parameters can be interfaced to master and slave microcontrollers working as an onboard computer at the transformer that can collect sensing data and send it to a hub monitoring the status of the transformers in power supply network to have continuous supply of power to consumers. The hub monitoring the transformer may be placed at the power distribution company and at the transformer manufacturer’s site to assess the performance of transformers statistically and take corrective action where it is necessary. The CMS is intended to be easily incorporated into the transformer configurations, requiring little modification of the existing infrastructure and easily manageable through recalibration and replacement of sensors every now and then. The system does, however, require initial installation costs, but these are offset by many advantages that include increased transformer lifespan, less operational time lost, and improved energy efficiency, with payback expected within 2-3 years.

Ghulam Ishaq Khan Institute of Engineering Sciences and Technology (PK)
Ghulam Ishaq Khan Institute of Engineering Sciences and Technology
Affordable and clean energy
Openalex Percentile: Top 76%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Monitoring Magnetic Flux Density of 100 KVA Transformer Operational Remotely — Arsalan Arif, Ajmal Bangash, et al. · (2024) | TGRS Research Map | TGRS