Predicting retention on immobilized artificial membrane chromatography: Lipophilicity-based versus lipophilicity-independent models

Retention of molecules on immobilized artificial membrane (IAM) chromatography is a key physicochemical property for predictive models of permeability across biological barriers, with applications in drug design and ecotoxicology. Currently, IAM retention is solely experimentally determined, which limits its utility for screening virtual compound libraries or for predictions of yet not synthesized molecules. The present study focuses on developing predictive models of IAM retention factors (logk<sub>w(IAM)</sub>) for a structurally diverse set of drug compounds, scrutinizing the role of lipophilicity, experimental and calculated, as well as the contribution of additional molecular parameters, selected from a pool of physicochemical, constitutional, topological and 3D descriptors. After obtaining a data overview by principal component analysis, both multiple linear regression (MLR) and partial least squares (PLS) analyses were used to construct lipophilicity-based models and lipophilicity-independent models. Bulk, polarity and fraction of anionic species were common descriptors in all models. It was demonstrated that calculated lipophilicity values introduced additional uncertainty, depending on the software used. On the other hand, lipophilicity-independent MLR and PLS models, which relied solely on computational descriptors, showed comparable performance with lipophilicity-based models, while offering the advantage to more useful for screening large libraries in early drug discovery. The reliability of lipophilicity-independent MLR and PLS models was assessed by external validation as well as by using a blind test set. Error distribution between lipophilicity-based and lipophilicity-independent models was also investigated and found to be comparable, while it was better than the differences between experimental and calculated lipophilicity values.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2025-02-04
DOI
https://doi.org/10.1016/j.chroma.2025.465752
Citations
1
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predicting retention on immobilized artificial membrane chromatography: Lipophilicity-based versus lipophilicity-independent models

Theodosia Vallianatou, Fotios Tsopelas, Anna Tsantili-Kakoulidou
1 citations
Journal of Chromatography A
Analytical Chemistry and Chromatography
0.76
article

Predicting retention on immobilized artificial membrane chromatography: Lipophilicity-based versus lipophilicity-independent models

Theodosia Vallianatou, Fotios Tsopelas, Anna Tsantili-Kakoulidou
article en
1 citations

Abstract

Retention of molecules on immobilized artificial membrane (IAM) chromatography is a key physicochemical property for predictive models of permeability across biological barriers, with applications in drug design and ecotoxicology. Currently, IAM retention is solely experimentally determined, which limits its utility for screening virtual compound libraries or for predictions of yet not synthesized molecules. The present study focuses on developing predictive models of IAM retention factors (logk<sub>w(IAM)</sub>) for a structurally diverse set of drug compounds, scrutinizing the role of lipophilicity, experimental and calculated, as well as the contribution of additional molecular parameters, selected from a pool of physicochemical, constitutional, topological and 3D descriptors. After obtaining a data overview by principal component analysis, both multiple linear regression (MLR) and partial least squares (PLS) analyses were used to construct lipophilicity-based models and lipophilicity-independent models. Bulk, polarity and fraction of anionic species were common descriptors in all models. It was demonstrated that calculated lipophilicity values introduced additional uncertainty, depending on the software used. On the other hand, lipophilicity-independent MLR and PLS models, which relied solely on computational descriptors, showed comparable performance with lipophilicity-based models, while offering the advantage to more useful for screening large libraries in early drug discovery. The reliability of lipophilicity-independent MLR and PLS models was assessed by external validation as well as by using a blind test set. Error distribution between lipophilicity-based and lipophilicity-independent models was also investigated and found to be comparable, while it was better than the differences between experimental and calculated lipophilicity values.

Journal of Chromatography AVol. 1745
National Technical University of Athens (GR), National and Kapodistrian University of Athens (GR), Science for Life Laboratory (SE)
Stiftelsen Lars Hiertas Minne
Openalex Percentile: Top 35%
Analytical Chemistry and Chromatography
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.