Perbedaan Nilai Dosis Radiasi Permukaan Kulit Gonad pada Radiografi Abdomen Antero Posterior pada Nilai mA dan s Berbeda dengan Nilai mAs yang Sama

Background: Abdominal radiography examination is one of the examinations that is often carried out and contains radiosensitive organs, namely the gonads. Milli Ampere Second (mAs) is one of the parameters regulated in making radiographs besides kV. mAs is the product of mA and s and there are often variations in the use of mA and s values to produce the same mAs value. This study's objective was to identifythe difference in radiation dose values for the surface of the gonad skin on anteroposterior abdominal radiographs with changes in different combinations of mA and s values.sMethods: This is pre-experimental quantitative research. The research object is body phantom. Data were collected by exposing abdomen radiography the body phantom and measured the amount of radiation dose to the skin surface of the gonad. mA and s setting : 160 mA 125 ms; 200 mA 100 ms; dan 250 mA 80 ms. Data analysis was carried out using statistical tests.Results: The average radiation dose to the skin surface of the gonad organs in the combination is 160 mA 125 ms; 200 mA 100 ms; and 250 mA 80 ms, namely 883.27 µGy; 883.09 µGy; and 883.72 µGy. Statistical test results show there is no significant difference between the combination of 160 mA 125 ms; 200 mA 100 ms; and 250 mA 80 ms, namely 883.27 µGy; 883.09 µGy with a significance of 0.748 (p-value 0.05). mAs determine the intensity of X-rays; the number of X-rays produced is proportional to milliamperes. As long as the mAs value remains constant, the amount of radiation intensity produced is the same, and the radiation dose is sameConclusions: There is no significant difference in the value of radiation dose to the skin surface of the gonad area on abdominal radiography with different combinations of mA and s values at the same mAs value

Authors

Institutions

Publication Details

Journal
Jurnal Imejing Diagnostik (JImeD)
Published
2025-02-04
DOI
https://doi.org/10.31983/jimed.v1i1.12308
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perbedaan Nilai Dosis Radiasi Permukaan Kulit Gonad pada Radiografi Abdomen Antero Posterior pada Nilai mA dan s Berbeda dengan Nilai mAs yang Sama

Susi Tri Isnoviasih, Panji Wibowo Nurcahyo, Angga Yosainto Bequet, M. Puspita et al.
Jurnal Imejing Diagnostik (JImeD)
Radiomics and Machine Learning in Medical Imaging
article

Perbedaan Nilai Dosis Radiasi Permukaan Kulit Gonad pada Radiografi Abdomen Antero Posterior pada Nilai mA dan s Berbeda dengan Nilai mAs yang Sama

Susi Tri Isnoviasih, Panji Wibowo Nurcahyo, Angga Yosainto Bequet, M. Puspita, Nabila Pramitya Putri, Widya Mufida
article en

Abstract

Background: Abdominal radiography examination is one of the examinations that is often carried out and contains radiosensitive organs, namely the gonads. Milli Ampere Second (mAs) is one of the parameters regulated in making radiographs besides kV. mAs is the product of mA and s and there are often variations in the use of mA and s values to produce the same mAs value. This study's objective was to identifythe difference in radiation dose values for the surface of the gonad skin on anteroposterior abdominal radiographs with changes in different combinations of mA and s values.sMethods: This is pre-experimental quantitative research. The research object is body phantom. Data were collected by exposing abdomen radiography the body phantom and measured the amount of radiation dose to the skin surface of the gonad. mA and s setting : 160 mA 125 ms; 200 mA 100 ms; dan 250 mA 80 ms. Data analysis was carried out using statistical tests.Results: The average radiation dose to the skin surface of the gonad organs in the combination is 160 mA 125 ms; 200 mA 100 ms; and 250 mA 80 ms, namely 883.27 µGy; 883.09 µGy; and 883.72 µGy. Statistical test results show there is no significant difference between the combination of 160 mA 125 ms; 200 mA 100 ms; and 250 mA 80 ms, namely 883.27 µGy; 883.09 µGy with a significance of 0.748 (p-value 0.05). mAs determine the intensity of X-rays; the number of X-rays produced is proportional to milliamperes. As long as the mAs value remains constant, the amount of radiation intensity produced is the same, and the radiation dose is sameConclusions: There is no significant difference in the value of radiation dose to the skin surface of the gonad area on abdominal radiography with different combinations of mA and s values at the same mAs value

Jurnal Imejing Diagnostik (JImeD)Vol. 1(1)
Politeknik Kesehatan Kemenkes Semarang (ID)
Openalex Percentile: Top 97%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.