Analisis Informasi Citra Anatomi Ureter antara Safire dengan Filtered Back Projection pada Teknik Tracking CT Urologi Klinis Hidronefrosis

Background: Clinical CT-Scan Examination and Noise Reduction in Hydronephrosis. Non-contrast CT-Scan examination is used to diagnose hydronephrosis and enhance diagnostic information in CT Urology tracking. However, CT Urography images often contain high noise levels due to examination parameters and patient size variations, which can obscure small anatomical details like the ureter. To improve image quality, reconstruction algorithms such as Filtered Back Projection (FBP) and Iterative Reconstruction (IR), particularly SAFIRE, are used alongside denoising techniques to reduce noise while preserving diagnostic information.This research aims to find the most optimal reconstruction algorithm for processing images regarding ureter anatomical information in tracking CT Urology techniques for clinical hydronephrosis.Methods: This is a quasi-experiment using the static group comparison method. Non-contrast CT (NCCT) Urology examination images in hydronephrosis patients were processed with FBP and SAFIRE strength 3 reconstruction algorithms. Assessment of anatomical image information analysis was conducted quantitatively by measuring noise and assessing anatomical information by respondents.Results: The results of this study are differences in anatomical information on Urology CT tracking images with variations in FBP and SAFIRE reconstruction algorithms with a p-value of 0.00 (0.05 The study results showed significant differences in ureter anatomical information between CT Urology tracking images reconstructed with FBP and SAFIRE algorithms (p-value = 0.00 0.05). The alternative hypothesis was accepted, indicating that SAFIRE is more effective than FBP in reducing noise in CT Urology tracking images.Conclusions: SAFIRE produces higher image quality and lower noise in non-contrast CT Urology.

Authors

Institutions

Publication Details

Journal
Jurnal Imejing Diagnostik (JImeD)
Published
2025-02-04
DOI
https://doi.org/10.31983/jimed.v1i1.11684
Primary Topic
Computer Science and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Informasi Citra Anatomi Ureter antara Safire dengan Filtered Back Projection pada Teknik Tracking CT Urologi Klinis Hidronefrosis

A H Sulistiyadi, Agustina Dwi Prastanti, Sudiyono Sudiyono, Rasyid Rasyid et al.
Jurnal Imejing Diagnostik (JImeD)
Computer Science and Engineering
article

Analisis Informasi Citra Anatomi Ureter antara Safire dengan Filtered Back Projection pada Teknik Tracking CT Urologi Klinis Hidronefrosis

A H Sulistiyadi, Agustina Dwi Prastanti, Sudiyono Sudiyono, Rasyid Rasyid, Putri Vina Zakiah, Maya Susanti
article en

Abstract

Background: Clinical CT-Scan Examination and Noise Reduction in Hydronephrosis. Non-contrast CT-Scan examination is used to diagnose hydronephrosis and enhance diagnostic information in CT Urology tracking. However, CT Urography images often contain high noise levels due to examination parameters and patient size variations, which can obscure small anatomical details like the ureter. To improve image quality, reconstruction algorithms such as Filtered Back Projection (FBP) and Iterative Reconstruction (IR), particularly SAFIRE, are used alongside denoising techniques to reduce noise while preserving diagnostic information.This research aims to find the most optimal reconstruction algorithm for processing images regarding ureter anatomical information in tracking CT Urology techniques for clinical hydronephrosis.Methods: This is a quasi-experiment using the static group comparison method. Non-contrast CT (NCCT) Urology examination images in hydronephrosis patients were processed with FBP and SAFIRE strength 3 reconstruction algorithms. Assessment of anatomical image information analysis was conducted quantitatively by measuring noise and assessing anatomical information by respondents.Results: The results of this study are differences in anatomical information on Urology CT tracking images with variations in FBP and SAFIRE reconstruction algorithms with a p-value of 0.00 (0.05 The study results showed significant differences in ureter anatomical information between CT Urology tracking images reconstructed with FBP and SAFIRE algorithms (p-value = 0.00 0.05). The alternative hypothesis was accepted, indicating that SAFIRE is more effective than FBP in reducing noise in CT Urology tracking images.Conclusions: SAFIRE produces higher image quality and lower noise in non-contrast CT Urology.

Jurnal Imejing Diagnostik (JImeD)Vol. 1(1)
Rumah Sakit Umum Pusat Dr. Sardjito (ID), Politeknik Kesehatan Kemenkes Semarang (ID)
Openalex Percentile: Top 99%
Computer Science and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.