Exploring spatial dose information in the parotid gland for xerostomia prediction and local dose patterns in head and neck cancer radiotherapy

<i>Purpose</i>. To investigate the relationship between spatial parotid dose and the risk of xerostomia in patients undergoing head-and-neck cancer radiotherapy, using machine learning (ML) methods.<i>Methods</i>. Prior to conducting voxel-based ML analysis of the spatial dose, two steps were taken: (1) The parotid dose was standardized through deformable image registration to a reference patient; (2) Bilateral parotid doses were regrouped into contralateral and ipsilateral portions depending on their proximity to the gross tumor target. Individual dose voxels were input into six commonly used ML models, which were tuned with ten-fold cross validation: random forest (RF), ridge regression (RR), support vector machine (SVM), extra trees (ET), k-nearest neighbor (kNN), and naïve Bayes (NB). Binary endpoints from 240 patients were used for model training and validation: 0 (N = 119) for xerostomia grades 0 or 1, and 1 (N = 121) for grades 2 or higher. Model performance was evaluated using multiple metrics, including accuracy, F<sub>1</sub>score, areas under the receiver operating characteristics curves (auROC), and area under the precision-recall curves (auPRC). Dose voxel importance was assessed to identify local dose patterns associated with xerostomia risk.<i>Results</i>. Four models, including RF, SVM, ET, and NB, yielded average auROCs and auPRCs greater than 0.60 from ten-fold cross-validation on the training data, except for a lower auROC from NB. The first three models, along with kNN, demonstrated higher accuracy and F<sub>1</sub>scores. A bootstrapping analysis confirmed test uncertainty. Voxel importance analysis from kNN indicated that the posterior portion of the ipsilateral gland was more predictive of xerostomia, but no clear patterns were identified from the other models.<i>Conclusion</i>. Voxel doses as predictors of xerostomia were confirmed with some ML classifiers, but no clear regional patterns could be established among these classifiers, except kNN. Further research with a larger patient dataset is needed to identify conclusive patterns.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-02-03
DOI
https://doi.org/10.1088/2057-1976/adb15e
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring spatial dose information in the parotid gland for xerostomia prediction and local dose patterns in head and neck cancer radiotherapy

Lewis E. Tomalin, Ming Chao, José Peñagarícano, Jerry Liu et al.
1 citations
Biomedical Physics & Engineering Express
Advanced Radiotherapy Techniques
1.88
article

Exploring spatial dose information in the parotid gland for xerostomia prediction and local dose patterns in head and neck cancer radiotherapy

Lewis E. Tomalin, Ming Chao, José Peñagarícano, Jerry Liu, Jie Wei, Jingliang Zhang, Tian Liu
article en
1 citations

Abstract

<i>Purpose</i>. To investigate the relationship between spatial parotid dose and the risk of xerostomia in patients undergoing head-and-neck cancer radiotherapy, using machine learning (ML) methods.<i>Methods</i>. Prior to conducting voxel-based ML analysis of the spatial dose, two steps were taken: (1) The parotid dose was standardized through deformable image registration to a reference patient; (2) Bilateral parotid doses were regrouped into contralateral and ipsilateral portions depending on their proximity to the gross tumor target. Individual dose voxels were input into six commonly used ML models, which were tuned with ten-fold cross validation: random forest (RF), ridge regression (RR), support vector machine (SVM), extra trees (ET), k-nearest neighbor (kNN), and naïve Bayes (NB). Binary endpoints from 240 patients were used for model training and validation: 0 (N = 119) for xerostomia grades 0 or 1, and 1 (N = 121) for grades 2 or higher. Model performance was evaluated using multiple metrics, including accuracy, F<sub>1</sub>score, areas under the receiver operating characteristics curves (auROC), and area under the precision-recall curves (auPRC). Dose voxel importance was assessed to identify local dose patterns associated with xerostomia risk.<i>Results</i>. Four models, including RF, SVM, ET, and NB, yielded average auROCs and auPRCs greater than 0.60 from ten-fold cross-validation on the training data, except for a lower auROC from NB. The first three models, along with kNN, demonstrated higher accuracy and F<sub>1</sub>scores. A bootstrapping analysis confirmed test uncertainty. Voxel importance analysis from kNN indicated that the posterior portion of the ipsilateral gland was more predictive of xerostomia, but no clear patterns were identified from the other models.<i>Conclusion</i>. Voxel doses as predictors of xerostomia were confirmed with some ML classifiers, but no clear regional patterns could be established among these classifiers, except kNN. Further research with a larger patient dataset is needed to identify conclusive patterns.

Biomedical Physics & Engineering ExpressVol. 11(2)
City College of New York (US), Moffitt Cancer Center (US), Icahn School of Medicine at Mount Sinai (US)
Radiation Oncology Institute
Openalex Percentile: Top 21%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.