Stochastic variational inference improves quantification of multiple timepoint arterial spin labelling perfusion MRI

Multiple-timepoint arterial spin labelling MRI is a non-invasive imaging technique that permits measurement of both cerebral blood flow and arterial transit time, the latter of which is an emerging biomarker of interest for cerebrovascular health. Quantification of arterial spin labelling data is challenging due to the low signal to noise ratio and non-linear tracer kinetics of this technique. In this work, we introduce a new quantification method called SSVB that addresses limitations in existing methods and demonstrate its performance using simulations and acquisition data. Simulations showed that the method is more accurate, particularly for estimating arterial transit time, and more robust to noise than existing techniques. On high spatial resolution data acquired at 3 T, the method produced less noisy parameter maps than the comparator method and captured greater variation in arterial transit time on a cross-sectional cohort.

Authors

Institutions

Publication Details

Journal
Frontiers in Neuroscience
Published
2025-02-04
DOI
https://doi.org/10.3389/fnins.2025.1536752
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stochastic variational inference improves quantification of multiple timepoint arterial spin labelling perfusion MRI

Michael A. Chappell, Georgia Kenyon, Martin Craig, Thomas Kirk
Frontiers in Neuroscience
Advanced MRI Techniques and Applications
article

Stochastic variational inference improves quantification of multiple timepoint arterial spin labelling perfusion MRI

Michael A. Chappell, Georgia Kenyon, Martin Craig, Thomas Kirk
article en

Abstract

Multiple-timepoint arterial spin labelling MRI is a non-invasive imaging technique that permits measurement of both cerebral blood flow and arterial transit time, the latter of which is an emerging biomarker of interest for cerebrovascular health. Quantification of arterial spin labelling data is challenging due to the low signal to noise ratio and non-linear tracer kinetics of this technique. In this work, we introduce a new quantification method called SSVB that addresses limitations in existing methods and demonstrate its performance using simulations and acquisition data. Simulations showed that the method is more accurate, particularly for estimating arterial transit time, and more robust to noise than existing techniques. On high spatial resolution data acquired at 3 T, the method produced less noisy parameter maps than the comparator method and captured greater variation in arterial transit time on a cross-sectional cohort.

Frontiers in NeuroscienceVol. 19
University of Nottingham (GB), The University of Adelaide (AU)
Washington University in St. Louis, UK Research and Innovation, National Institutes of Health, Medical Research Council, Engineering and Physical Sciences Research Council, National Institute of Mental Health
Good health and well-being
Openalex Percentile: Top 97%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.